RF31 Hope Microelectronics co., Ltd, RF31 Datasheet - Page 45

no-image

RF31

Manufacturer Part Number
RF31
Description
Rf31 Ism Receiver
Manufacturer
Hope Microelectronics co., Ltd
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RF3100
Manufacturer:
RFMD
Quantity:
15 520
Part Number:
RF3100
Manufacturer:
ST-ERICSS
Quantity:
4 288
Part Number:
RF3100
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
RF3100-2
Quantity:
2 219
Part Number:
RF3100-2
Manufacturer:
RFMD
Quantity:
1 173
Part Number:
RF3100-2
Manufacturer:
RFMD
Quantity:
20 000
Part Number:
RF3100-2SR
Manufacturer:
RFMD
Quantity:
213
Part Number:
RF3100-2TR13
Manufacturer:
RFMD
Quantity:
15 540
Part Number:
RF3100-2TR13
Manufacturer:
RFMD
Quantity:
1 985
Part Number:
RF3100-2TR13
Manufacturer:
RFMD
Quantity:
20 000
Part Number:
RF3103
Manufacturer:
RFMD
Quantity:
20 000
8.3. General Purpose ADC
An 8-bit SAR ADC is integrated onto the chip for general purpose use, as well as for digitizing the temperature
sensor reading. ―Register 0Fh. ADC Configuration,‖ must be configured depending on the use of the GP ADC before
use. The architecture of the ADC is demonstrated in Figure 18. First the input of the ADC must be selected by setting
the ADCSEL[2:0] depending on the use of the ADC. For instance, if the ADC is going to be used to read out the
internal temperature sensor, then ADCSEL[2:0] should be set to 000. Next, the input reference voltage to the ADC
must be chosen. By default, the ADC uses the bandgap voltage as a reference so the input range of the ADC is from
0–1.02 V with an LSB resolution of 4 mV (1.02/255). Changing the ADC reference will change the LSB resolution
accordingly.
Every time the ADC conversion is desired, the ADCStart bit in ―Register 0Fh. ADC Configuration,‖ must be set to 1.
This is a self clearing bit that will be cleared at the end of the conversion cycle of the ADC. The conversion time for
the ADC is 350 us. After the 350 us or when the ADCstart/busy bit is cleared, then the ADC value may be read out of
"Register 11h. ADC Value". Setting the "Register 10h. ADC Sensor Amplifier Offset", ADC Sensor Amplifier Offset is
only necessary when the ADC is configured to used as a Bridge Sensor as described in the following section.
Add
0F
10
11
R/W
R/W
R/W
R
Tel: +86-755-82973805
Amplifier Offset
Function/D
escription
Configuration
ADC Sensor
ADC Value
ADC
adcstart/ad
Figure 18. General Purpose ADC Architecture
cbusy
adc[7]
D7
Fax: +86-755-82973550
adcsel
adc[6]
D6
[2]
adcsel
adc[5]
D5
[1]
adcsel
adc[4]
E-mail: sales@hoperf.com
D4
[0]
adcoffs[3
adcref[1]
adc[3]
D3
]
adcref[0]
adcoffs[
adc[2]
D2
2]
http://www.hoperf.com
adcgain[1]
adcoffs[1]
adc[1]
D1
R F 3 1
adcgain[0]
adcoffs[0]
adc[0]
D0
POR
Def.
00h
00h
45

Related parts for RF31