RF31 Hope Microelectronics co., Ltd, RF31 Datasheet - Page 50

no-image

RF31

Manufacturer Part Number
RF31
Description
Rf31 Ism Receiver
Manufacturer
Hope Microelectronics co., Ltd
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RF3100
Manufacturer:
RFMD
Quantity:
15 520
Part Number:
RF3100
Manufacturer:
ST-ERICSS
Quantity:
4 288
Part Number:
RF3100
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
Part Number:
RF3100-2
Quantity:
2 219
Part Number:
RF3100-2
Manufacturer:
RFMD
Quantity:
1 173
Part Number:
RF3100-2
Manufacturer:
RFMD
Quantity:
20 000
Part Number:
RF3100-2SR
Manufacturer:
RFMD
Quantity:
213
Part Number:
RF3100-2TR13
Manufacturer:
RFMD
Quantity:
15 540
Part Number:
RF3100-2TR13
Manufacturer:
RFMD
Quantity:
1 985
Part Number:
RF3100-2TR13
Manufacturer:
RFMD
Quantity:
20 000
Part Number:
RF3103
Manufacturer:
RFMD
Quantity:
20 000
8.5. Low Battery Detector
A low battery detector (LBD) with digital read-out is integrated into the chip. A digital threshold may be programmed
into the lbdt[4:0] field in "Register 1Ah. Low Battery Detector Threshold". When the digitized battery voltage
reaches this threshold an interrupt will be generated on the nIRQ pin to the microcontroller. The microcontroller will
then need to verify the interrupt by reading "Register 03h. Interrupt/Status 1" and ―Register 04h. Interrupt/Status
If the LBD is enabled while the chip is in SLEEP mode, it will automatically enable the RC oscillator which will
periodically turn on the LBD circuit to measure the battery voltage. The battery voltage may also be read out
through "Register 1Bh. Battery Voltage Level" at any time when the LBD is enabled. The Low Battery Detect
function is enabled by setting enlbd=1 in "Register 07h. Operating Mode and Function Control 1".
The LBD output is digitized by a 5-bit ADC. When the LBD function is enabled, enlbd = 1 in "Register 07h.
Operating Mode and Function Control 1", the battery voltage may be read at anytime by reading "Register 1Bh.
Battery Voltage Level". A Battery Voltage Threshold may be programmed to register 1Ah. When the battery voltage
level drops below the battery voltage threshold an interrupt will be generated on nIRQ pin to the microcontroller if
the LBD interrupt is enabled in ―Register 06h. Interrupt Enable
interrupt by reading the interrupt status register, Addresses 03 and 04H. The LSB step size for the LBD ADC is 50
mV, with the ADC range demonstrated in the table below. If the LBD is enabled the LBD and ADC will automatically
be enabled every 1 s for approximately 250 μs to measure the voltage which minimizes the current consumption in
Sensor mode. Before an interrupt is activated four consecutive readings are required.
Ad
1A
1B
R/W
R/W
R
Tel: +86-755-82973805
Detector Threshold
Function/Descri
Battery Voltage
Low Battery
ption
Level
BatteryVoltage =1.7+50mV
Fax: +86-755-82973550
ADC Value
D7
0
……
29
30
31
0
1
2
D6
0
D5
0
E-mail: sales@hoperf.com
vbat[4]
lbdt[4]
D4
2,‖.
×
VDD Voltage [V]
The microcontroller will then need to verify the
vbat[3]
lbdt[3]
ADCValue
D3
1.7–1.75
1.75–1.8
3.1–3.15
3.15–3.2
< 1.7
……
>3.2
vbat[2]
lbdt[2]
D2
http://www.hoperf.com
vbat[1]
lbdt[1]
D1
R F 3 1
vbat[0]
lbdt[0]
D0
POR
Def.
14h