P1200S Teccor Electronics, P1200S Datasheet - Page 128
P1200S
Manufacturer Part Number
P1200S
Description
solid state crowbar devices
Manufacturer
Teccor Electronics
Datasheet
1.P1200S.pdf
(212 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
P1200SA
Manufacturer:
Littelfu
Quantity:
150 000
Company:
Part Number:
P1200SAL
Manufacturer:
Littelfu
Quantity:
150 000
Company:
Part Number:
P1200SALRP
Manufacturer:
Littelfu
Quantity:
74 500
Company:
Part Number:
P1200SB
Manufacturer:
Littelfu
Quantity:
150 000
Company:
Part Number:
P1200SBL
Manufacturer:
Littelfu
Quantity:
150 000
- Current page: 128 of 212
- Download datasheet (2Mb)
GR 1089–Core
Table 4.1 Test Conditions
Notes:
• When performing longitudinal tests, the test generator will have a dual output.
• Refer to Table 4.2 for switch positions for each test condition.
Table 4.2 Connections to Test Generator
Note: Other outside plant leads associated with the unit should be grounded during the test and the test repeated with these leads
Figure 4.1 Connection Appearances
http://www.teccor.com
+1 972-580-7777
Condition A-1 of Table 4.1
Condition A-2 of Table 4.1
Condition A-3 of Table 4.1
Test
A
B
terminated as in service. Leads that do not connect to outside plant should be terminated as appropriate for the operating
mode(s) of the unit.
1. Tip to Generator, Ring to Ground
2. Ring to Generator, Tip to Ground
3. Tip and Ring to Generator simultaneously
Tip and Ring to Generator simultaneously
Voltage
Source
Condition
Test Generator
(If Specified)
Resistance
Limiting
Passing Criteria
Passing criteria for the First Level Lightning Surge Test and the First Level AC Power Fault
Test is that the EUT will not be damaged and that it will operate as intended after the stress
is removed. Passing criteria for the Second Level Lightning Surge Test and Second Level
Two-wire Interface
S1
S3
Closed
Closed
Open
S1
S2
S4
Ring
Tip
4 - 4
1. Each lead (T, R, T
2. Tip and Ring to Generator, simultaneously; T
3. T
T, R, T
leads grounded
Ground
Ground
1
Closed
Open
Open
and R
S2
1
, R
1
1
to Generator simultaneously
Switch Unit
Under Test
to Generator, simultaneously; Tip and Ring to
SIDACtor
1
, R
Four-wire Interface
1
) to the Generator with the other three
Closed
Closed
Open
S3
®
Data Book and Design Guide
© 2002 Teccor Electronics
Associated
Outside
Plant
Leads
1
and R
T
E
R
M
Closed
Open
Open
S4
1
to
T
E
R
M
Related parts for P1200S
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Cross Reference Data to Teccor Part Numbers (See datasheet appendix)
Manufacturer:
Teccor Electronics
Datasheet:
Part Number:
Description:
Cross Reference Data to Teccor Part Numbers (See datasheet appendix)
Manufacturer:
Teccor Electronics
Datasheet:
Part Number:
Description:
Cross Reference Data to Teccor Part Numbers (See datasheet appendix)
Manufacturer:
Teccor Electronics
Datasheet:
Part Number:
Description:
Manufacturer:
Teccor Electronics
Datasheet:
Part Number:
Description:
solid state crowbar devices
Manufacturer:
Teccor Electronics
Datasheet:
Part Number:
Description:
Sensitive SCRs (0.8 A to 10 A) S6S1Sensitive SCRs
Manufacturer:
Teccor Electronics
Datasheet: