AD9516-3 Analog Devices, AD9516-3 Datasheet - Page 66

no-image

AD9516-3

Manufacturer Part Number
AD9516-3
Description
14-Output Clock Generator
Manufacturer
Analog Devices
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9516-3
Quantity:
5 510
Part Number:
AD9516-3
Manufacturer:
TI
Quantity:
5 510
Part Number:
AD9516-3BCPZ
Manufacturer:
AD
Quantity:
148
Part Number:
AD9516-3BCPZ
Manufacturer:
ADI
Quantity:
648
Part Number:
AD9516-3BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Reg.
Addr
(Hex) Bit(s) Name
1C
1C
1C
1C
1C
1C
1C
1C
1D
AD9516-3
<7>
<6>
<5>
<4>
<3>
<2>
<1>
<0>
<4>
Disable
Switchover
Deglitch
Select REF2
Use REF_SEL If Register 0x1C<4> = 0 (manual), set method of PLL reference selection.
Pin
Automatic
Reference
Switchover
Stay on REF2
REF2
Power On
REF1
Power On
Differential
Reference
PLL Status
Register
Disable
Description
<4> <3> <2>
1
1
1
1
1
1
1
1
1
1
1
1
Disable or enable the switchover deglitch circuit.
<7> = 0; enable switchover deglitch circuit.
<7> = 1; disable switchover deglitch circuit.
If Register 0x1C<5> = 0, select reference for PLL.
<6> = 0; select REF1.
<6> = 1; select REF2.
<5> = 0; use Register 0x1C<6>.
<5> = 1; use REF_SEL pin.
Automatic or manual reference switchover. Single-ended reference mode must be selected by
Register 0x1C<0> = 0.
<4> = 0; manual reference switchover.
<4> = 1; automatic reference switchover.
Stay on REF2 after switchover.
<3> = 0; return to REF1 automatically when REF1 status is good again.
<3> = 1; stay on REF2 after switchover. Do not automatically return to REF1.
When automatic reference switchover is disabled, this bit turns the REF2 power on.
<2> = 0; REF2 power off.
<2> = 1; REF2 power on.
When automatic reference switchover is disabled, this bit turns the REF1 power on.
<1> = 0; REF1 power off.
<1> = 1; REF1 power on.
Selects the PLL reference mode, differential or single-ended. Single-ended must be selected for the
automatic switchover or REF1 and REF2 to work.
<0> = 0; single-ended reference mode.
<0> = 1; differential reference mode.
Disables the PLL status register readback.
<4> = 0; PLL status register enable.
<4> = 1; PLL status register disable.
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
<1>
0
0
1
1
0
0
1
1
0
0
1
1
<0>
0
1
0
1
0
1
0
1
0
1
0
1
Level or
Dynamic
Signal
DYN
LVL
LVL
LVL
LVL
LVL
LVL
LVL
LVL
LVL
LVL
LVL
Rev. 0 | Page 66 of 84
Signal at REFMON Pin
Unselected reference to PLL (not available when in
differential mode).
Status of selected reference (status of differential reference);
active low.
Status of unselected reference (not available in differential mode);
active low.
Status of REF1 frequency (active low).
Status of REF2 frequency (active low).
(Status of REF1 frequency) AND (Status of REF2 frequency) .
(DLD) AND (Status of selected reference) AND (Status of VCO) .
Status of VCO frequency (active low).
Selected reference (low = REF2, high = REF1).
Digital lock detect (DLD); active low.
Holdover active (active low).
LD pin comparator output (active low).

Related parts for AD9516-3