WT30-FT011 Omron Electronics Inc-IA Div, WT30-FT011 Datasheet - Page 3

no-image

WT30-FT011

Manufacturer Part Number
WT30-FT011
Description
Specifications: Lead Free Status: Lead Free ; RoHS Status: RoHS Compliant
Manufacturer
Omron Electronics Inc-IA Div
Datasheet
Nomenclature
■ Serial Master Station
■ I/O Slave Station
Status
indicators
Status
indicators
Antenna terminal (ANT1)
Mode selection switch
Switch between RUN,
TEST, and SET mode.
Mode selection switch
Switch between RUN,
TEST, and SET mode.
Antenna terminal (ANT1)
Power supply terminal
Supply power to the WT30.
Power supply terminal
Supply power to the WT30
and output circuits.
Serial communications
setting switch
Set the baud rate.
I/O terminals
Connect the contact
signals.
Unit No. switch
Set the unit number of the Serial Master Station.
RS-232C Terminal
Connect the PLC, personal computer, etc.
Node setting switch (WNODE)
Set the unit number of the I/O Slave Station.
Node setting switch (WNODE)
Set the number of connected I/O Slave Stations.
I/O terminal status indicators (0 to 7 or 8 to 15)
The contact status is displayed.
Function setting switch
Make the detailed settings
for RUN/TEST mode.
Function setting switch
Make the detailed settings
for RUN/TEST/SET mode.
Channel setting switch (WCH)
Set the communications frequency.
Channel setting switch (WCH)
Set the communications frequency
channel.
Special function switch
Antenna terminal (ANT2)
Antenna terminal (ANT2)
Special
function
switch
Received
signal
strength
indicator
Received
signal
strength
indicator
■ Unit No. Switch
Set the unit number of the Serial Master Station
Default: 00
■ Node Setting Switch (WNODE)
Set the number of connected I/O Slave Stations.
Set the node number of the Slave Stations being used as I/O Slave
Stations. The Slave Station functions as a relay station when the
node number is set to 99.
Default: 01
■ Channel Setting Switch (WCH)
Set the communications frequency.
Default: 02
■ Function Setting Switch
Serial Master Station
I/O Slave Station
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7 to
10
No.
No.
RUN mode Holds I/O status data
TEST mode Signal strength monitor
SET mode
Not used
RUN mode Holds I/O status data
TEST mode Signal strength monitor
Not used
Applicable
Applicable
FA Wireless SS Terminals
mode
mode
when a
communications error
occurs.
Enable scan list
Relays used
disabled
All channels
automatically switched
---
Scan list recognition
Registers specified I/O
slave
Recognizes serial
numbers
---
when a
communications error
occurs.
Input hold
Input filter: 100 ms
disabled
All channels
automatically switched
Installation test
function
---
ON functions
ON functions
WT30
Clears I/O status data
when a
communications error
occurs.
Normal mode
Input filter: 10 ms
Signal strength monitor
enabled
Specified channels
Nothing done
---
Clears I/O status data
when a
communications error
occurs.
Disable scan list
Relays not used
Signal strength monitor
enabled
Specified channels
---
Nothing done
Registers all I/O slaves
automatically
Ignores serial numbers
---
OFF functions
OFF functions
3