■ Serial Communications Setting
Note: For example, if pins number 2, 3, and 4 are all ON, the total is
4
1
2
3
4
5
6
7
8
No.
Switch
7, which corresponds to a baud rate of 115,200 bps.
Communications setting
selection
Baud rate (bps)
(See note.)
Total value = 0: 1,200
Data length
Parity
Stop bits
FA Wireless SS Terminals
Function
= 1: 2,400
= 2: 4,800
= 3: 9,600
= 4: 19,200
= 5: 38,400
= 6: 57,600
= 7: 115,200
Detailed
settings
(settings for
No. 2 to 8
used)
1
2
4
8 bits
None
Odd
1 bit
ON
Default settings
(baud rate: 9,600 bps;
data length: 7 bits;
parity: even; stop bits:
2)
Settings for No. 2 to 8
are ignored.
0
0
0
7 bits
Yes
Even
2 bits
WT30
OFF
■ Display
Note: When using the WD30 as the Serial Master Station, the ERR
PWR
ERR
(Slave Station)
COMM
(Master Station)
0 to 15
(Slave Station)
RSSI
MS
(Module Status)
WS
(Wireless
Status)
Indicator
indicator will light if normal I/O communications are not
possible due to an error in the host network.
Green Lit
Red
Yellow Lit
Yellow Lit/Not lit ON/OFF status for input or
Red/
Yellow/
Green
Green Lit
Red
---
Green Lit
Red
---
Color
Not lit
Lit
Not lit
Not lit
Lit/
All not lit
Flashing TEST mode or SET mode has
Lit
Flashing A non-fatal error has occurred
Not lit
Flashing Permission to join wireless
Lit
Flashing Error from which recovery is
Not lit
Status
Power is being supplied.
Power is not being supplied.
Error output is ON:
Wireless device error or
wireless communications
error. (See note)
No wireless device error or
wireless communications
error.
Serial communications in
progress.
No serial communications.
output signals
Receiving Signal Strength
Indicator monitor: Number of
indicators lit (receiving signal
strength 1 to 9)
Receiving signal strength less
than 0 to 1.
Communications are normal.
been activated.
A fatal error has occurred that
cannot be recovered from.
Replace the Unit
that can be recovered from by
resetting the system.
Power is not being supplied or
the system is resetting.
The station has joined the
wireless network.
network received from Serial
Master Station (Slave Station)
A fatal error has occurred that
cannot be recovered from.
possible
Wireless communications are
not in progress.
Meaning (primary error)