TS80C32X2 ATMEL Corporation, TS80C32X2 Datasheet - Page 25

no-image

TS80C32X2

Manufacturer Part Number
TS80C32X2
Description
8-bit Microcontroller ROMless
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TS80C32X2-LCB
Manufacturer:
ATMEL
Quantity:
2 144
Part Number:
TS80C32X2-LCB
Manufacturer:
ATMEL
Quantity:
5 800
Part Number:
TS80C32X2-LCB
Quantity:
6 990
Part Number:
TS80C32X2-LCB
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS80C32X2-LCB
Manufacturer:
XILINX
0
Part Number:
TS80C32X2-LCC
Manufacturer:
JRC
Quantity:
1 400
Part Number:
TS80C32X2-LCC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS80C32X2-LCE
Manufacturer:
TEMIC
Quantity:
37
Part Number:
TS80C32X2-LCE
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
TS80C32X2-LIB
Manufacturer:
Atmel
Quantity:
10 000
6.8 Power-Off Flag
The power-off flag allows the user to distinguish between a “cold start” reset and a “warm start” reset.
A cold start reset is the one induced by V
the device and could be generated for example by an exit from power-down.
The power-off flag (POF) is located in PCON register (See Table 13.). POF is set by hardware when V
from 0 to its nominal voltage. The POF can be set or cleared by software allowing the user to determine the type
of reset.
The POF value is only relevant with a Vcc range from 4.5V to 5.5V. For lower Vcc value, reading POF bit will
return indeterminate value.
PCON - Power Control Register (87h)
Reset Value = 00X1 0000b
Not bit addressable
Rev. C - 15 January, 2001
Number
SMOD1
Bit
7
6
5
4
3
2
1
0
7
Mnemonic
SMOD1
SMOD0
POF
GF1
GF0
IDL
Bit
SMOD0
PD
-
6
Serial port Mode bit 1
Serial port Mode bit 0
Reserved
Power-Off Flag
General purpose Flag
General purpose Flag
Power-Down mode bit
Idle mode bit
Set to select double baud rate in mode 1, 2 or 3.
Clear to select SM0 bit in SCON register.
Set to to select FE bit in SCON register.
The value read from this bit is indeterminate. Do not set this bit.
Clear to recognize next reset type.
Set by hardware when V
Cleared by user for general purpose usage.
Set by user for general purpose usage.
Cleared by user for general purpose usage.
Set by user for general purpose usage.
Cleared by hardware when reset occurs.
Set to enter power-down mode.
Clear by hardware when interrupt or reset occurs.
Set to enter idle mode.
5
-
CC
Table 13. PCON Register
switch-on. A warm start reset occurs while V
POF
CC
4
rises from 0 to its nominal voltage. Can also be set by software.
GF1
3
Description
GF0
2
TS80C31X2
PD
1
CC
is still applied to
IDL
CC
0
rises
25

Related parts for TS80C32X2