ST7577 Sitronix Technology, ST7577 Datasheet - Page 16

no-image

ST7577

Manufacturer Part Number
ST7577
Description
Dot Matrix LCD Controller/Driver
Manufacturer
Sitronix Technology
Datasheet
www.DataSheet4U.com
ST7577
START LINE ADDRESS CIRCUIT
This circuit assigns DDRAM a line address that is scanned first at the beginning of each frame. By setting Start Line
Address repeatedly, the display pattern looks like scrolling vertically in the screen without changing the contents of DDRAM
(refer to Figure 11). When setting the Start Line Address (with “Set Start Line” instruction), the data of the same specified
line address in DDRAM are transferred to the Display Data Latch Circuit at the beginning of each frame.
ADDRESSING
ST7577 will automatically increases the address when sequential access. This feature allows MPU to access the display
data in DDRAM continuously without setting the address before each access.
In horizontal addressing mode, the X address is automatically increased by 1 after each byte access (refer to Figure 8).
After the last X address (X=131), X address wraps around to 0 and Y address increases to the next page. After the very last
address (X=131, Y=4), the address pointers wrap around to the original address (X=0, Y=0).
In vertical addressing mode, the Y address is automatically increased by 1 after each byte access (refer to Figure 9). After
the last Y address (Y=4), Y address wraps around to 0 and X address increases to the next column. After the very last
address (X=131, Y=4), the address pointers wrap around to the original address (X=0, Y=0).
Figure 8
Addressing Mode: Horizontal (V=0)
Figure 9
Addressing Mode: Vertical (V=1)
Ver 1.0a
16/48
2008/02/14

Related parts for ST7577