UPA809 NEC, UPA809 Datasheet
UPA809
Related parts for UPA809
UPA809 Summary of contents
Page 1
... PART NUMBER QUANTITY PA809T Loose products (50 PCS) PA809T-T1 Taping products (3 KPCS/Reel) Remark If you require an evaluation sample, please contact an NEC Sales Representative. (Unit sample quantity is 50 pcs.) ABSOLUTE MAXIMUM RATINGS (T PARAMETER Collector to Base Voltage Collector to Emitter Voltage Emitter to Base Voltage Collector Current ...
Page 2
... Insertion Power Gain ( Noise Figure (1) NF Noise Figure ( Ratio FE1 FE2 Notes 1. Pulse Measurement Measured with 3-pin bridge, emitter and case should be connected to guard pin of bridge. h CLASSIFICATION FE Rank KB Marking T88 h Value 80 to 160 CONDITION ...
Page 3
TYPICAL CHARACTERISTICS (T A TOTAL POWER DISSIPATION vs. AMBIENT TEMPERATURE Free Air 200 100 0 50 100 Ambient Temperature T (°C) A COLLECTOR CURRENT vs. COLLECTOR TO EMITTER VOLTAGE 30 200 A 180 A 160 A 20 140 A 120 ...
Page 4
NOISE FIGURE vs. COLLECTOR CURRENT GHz GHz Collector Current l (mA) C MAXIMUM AVAILABLE GAIN / INSERTION POWER GAIN vs. FREQUENCY 30 MAG ...
Page 5
S-PARAMETERS mA FREQUENCY S11 MHz MAG ANG 100.00 0.952 –18.2 200.00 0.913 –37.9 300.00 0.871 –55.6 400.00 0.817 –68.8 500.00 0.737 –82.6 600.00 0.657 –93.4 700.00 0.624 ...
Page 6
mA FREQUENCY S11 MHz MAG ANG 100.00 0.736 –44.1 200.00 0.603 –77.3 300.00 0.494 –100.6 400.00 0.415 –117.8 500.00 0.369 –133.0 600.00 0.350 –145.9 700.00 0.336 –155.9 ...
Page 7
mA FREQUENCY S11 MHz MAG ANG 100.00 0.924 –23.0 200.00 0.830 –46.1 300.00 0.750 –65.0 400.00 0.653 –79.4 500.00 0.548 –93.1 600.00 0.471 –104.2 700.00 0.433 –116.2 ...
Page 8
mA FREQUENCY S11 MHz MAG ANG 100.00 0.775 –34.3 200.00 0.609 –63.8 300.00 0.488 –83.7 400.00 0.390 –98.0 500.00 0.321 –111.7 600.00 0.277 –124.8 700.00 0.253 –136.0 ...
Page 9
PA809T 9 ...
Page 10
... Specific: Aircrafts, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices in “Standard“ unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact NEC Sales Representative in advance ...