(Hex) Bit(s) Name
0F3
0F3
0F4
0F4
0F4
0F5
0F5
0F5
[3:2]
[1:0]
[4]
[3:2]
[1:0]
[4]
[3:2]
[1:0]
OUT3 LVPECL
differential
voltage
OUT3
power-down [1]
OUT4 invert
OUT4 LVPECL
differential
voltage
OUT4 power-
down
OUT5 invert
OUT5 LVPECL
differential
voltage
OUT5 power-
down
Sets the LVPECL output differential voltage (V
[3]
0
0
1
1
LVPECL power-down modes.
0
0
1
1
Sets the output polarity.
[4] = 0; noninverting (default).
[4] = 1; inverting.
Sets the LVPECL output differential voltage (V
[3]
0
0
1
1
LVPECL power-down modes.
[1]
0
0
1
1
Sets the output polarity.
[4] = 0; noninverting (default).
[4] = 1; inverting.
Sets the LVPECL output differential voltage (V
[3]
0
0
1
1
LVPECL power-down modes.
[1]
0
0
1
1
Description
[2]
0
1
0
1
[0]
0
1
0
1
[2]
0
1
0
1
[0]
0
1
0
1
[2]
0
1
0
1
[0]
0
1
0
1
V
400
600
780 (default)
960
V
400
600
780 (default)
960
V
400
600
780 (default)
960
Mode
Normal operation.
Partial power-down, reference on; use only if there are no external load resistors.
Partial power-down, reference on, safe LVPECL power-down.
Total power-down, reference off; use only if there are no external load resistors.
OD
Mode
Normal operation.
Partial power-down, reference on; use only if there are no external load resistors.
Partial power-down, reference on, safe LVPECL power-down (default).
Total power-down, reference off; use only if there are no external load resistors.
Mode
Normal operation.
Partial power-down, reference on; use only if there are no external load resistors.
Partial power-down, reference on, safe LVPECL power-down (default).
Total power-down, reference off; use only if there are no external load resistors.
OD
OD
(mV)
(mV)
(mV)
Rev. 0 | Page 65 of 76
OD
OD
OD
).
).
).
AD9516-5
Output
On
Off
Off
Off
Output
On
Off
Off
Off
Output
On
Off
Off
Off