si5351 Silicon Laboratories, si5351 Datasheet - Page 17

no-image

si5351

Manufacturer Part Number
si5351
Description
Si5350a Factory-programmable Cmos Clock Generator
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
si5351A
0
Part Number:
si5351A-A-GT
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
si5351A-A-GTR
Manufacturer:
INFINEON
Quantity:
87
Part Number:
si5351A-B-GM
0
Part Number:
si5351A-B-GMR
0
Part Number:
si5351A-B-GTR
Manufacturer:
SILICON
Quantity:
12 000
Part Number:
si5351A-B-GTR
Manufacturer:
Silicon
Quantity:
220
Part Number:
si5351A-B-GTR
0
Company:
Part Number:
si5351A-B-GTR
Quantity:
40 000
Part Number:
si5351B-B-GM
0
Part Number:
si5351C-A-GM
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
si5351C-A-GU
Manufacturer:
Silicon Labs
Quantity:
135
8. Register Descriptions
Reset value = 0000 0000
Register 0. Interrupt Status Sticky
Name
3:2
1:0
Bit
Type
7
6
5
4
Bit
REVID[1:0] Revision ID. Device revision number. Set at the factory.
SYS_INIT System Initialization Status.
Reserved Reserved. Leave as default.
LOL_B
LOL_A
Name
SYS_INIT
LOS
D7
R
During power up the device copies the content of the NVM into RAM and performs a system
initialization. The device is not operational until initialization is complete. It is not recom-
mended to read or write registers in RAM through the I
plete. An interrupt will be triggered (INTR pin = 1, Si5351C only) during the system
initialization period.
0: System initialization is complete. Device is ready.
1: Device is in system initialization mode.
PLLB Loss Of Lock Status.
Si5351A/C only. PLLB will operate in a locked state when it has a valid reference from CLKIN
or XTAL. A loss of lock will occur if the frequency of the reference clock forces the PLL to
operate outside of its lock range as specified in Table 4, or if the reference clock fails to meet
the minimum requirements of a valid input signal as specified in Table 6. An interrupt will be
triggered (INTR pin = 1, Si5351C) during a LOL condition.
0: PLL B is locked.
1: PLL B is unlocked. When the device is in this state it will trigger an interrupt causing the
INTR pin to go high (Si5351C only).
PLL A Loss Of Lock Status.
PLL A will operate in a locked state when it has a valid reference from CLKIN or XTAL. A loss
of lock will occur if the frequency of the reference clock forces the PLL to operate outside of
its lock range as specified in Table 4, or if the reference clock fails to meet the minimum
requirements of a valid input signal as specified in Table 6. An interrupt will be triggered
(INTR pin = 1, Si5351C only) during a LOL condition.
0: PLL A is operating normally.
1: PLL A is unlocked. When the device is in this state it will trigger an interrupt causing the
INTR pin to go high (Si5351C only).
CLKIN Loss Of Signal (Si5351C Only).
A loss of signal status indicates if the reference clock fails to meet the minimum requirements
of a valid input signal as specified in Table 6. An interrupt will be triggered (INTR pin = 1,
Si5351C only) during a LOS condition.
0: Valid clock signal at the CLKIN pin.
1: Loss of signal detected at the CLKIN pin.
LOL_B
D6
R
LOL_A
D5
R
LOS
Rev. 0.1
D4
R
Function
D3
R
2
C interface until initialization is com-
D2
R
Si5351A/B/C
D1
R
REVID[1:0]
D0
R
17