smfl-86150ks Samwha Electric Co., Ltd., smfl-86150ks Datasheet - Page 11

no-image

smfl-86150ks

Manufacturer Part Number
smfl-86150ks
Description
A.c. Harmonic Filter
Manufacturer
Samwha Electric Co., Ltd.
Datasheet
Samwha
Samwha 38
This product is specially designed to accommodate high capacity to be
easily used for matching circuit of high frequency induction furnace
device.
For dielectric, polypropylene film and capacitor paper was used
together and aluminium foil electrode of non induction method was
used. For insulating oil,
non PCB dielectric was impregnation resulting in stable and excellent
feature.
For cooling method, it was designed that cooling water can absorb the
heat generated from the inner dielectric loss.
To make matching circuit easily when inductive load is changed, capacity was
divided into proper capacity and lead bushing was treated.
The material of case is non magnetic aluminum to minimize induction loss due
to high frequency electric filed. The loss of capacitor itself is about 0.1%.
Maximum Water temperature rise should not exceed 4deg[5l/min], on the
standard of maxim capacitance.
Permissible load power is 1.05 times of rated voltage [within1 hour per day]
and maximum permissible current is 1.35 times of rated current.
High frequency water cooling capacitor does not contain discharging resistor
since it is connected to high capacity coil circuit in paralleled.
When capacitor is input into circuit again, the permissible limit of residual voltage
should be within 10% of rated voltage and nuts with DC voltage.
Tightening strength on nuts at terminal is 200kg·㎝ or less.
Since the outer case of capacitor is unilateral electrode, please be sure to use the insulated rack in
installation.
When more than 2 capacitors are connected in paralleled, there should be space at least 35mm.
The flow quantity of cooling water shall be more than 5ℓ/min.
In case when capacitor is kept at subzero temperature, remove the water entirely from copper pipe
Flux of Cooling Water More than 5ℓ per minute
Ambient Temperature More than 0℃
Application
Technical data
Caution
Withstand Voltage
Installation place
Temperature of
Cooling Water
Cooling Water
Safety Device
Pressure of
Tolerance
Case
Creative TEchnology Provider
Only for Indoor
Cooling water exit temperature less than 45℃
Within ± 10% of rated capacity
2.15 times of rated voltage, 10 seconds
Less than 10kg/㎠
Thermostat contact capacity [250VAC, 7.5A]
Aluminium non painted product
4-8 Water Cooling Capacitor
Stream Flow
(ℓ/min)
<Head Loss and Cooling Water Quanfity Curve>
K : Series Logarithm of Coolling Coil
Notes) Pipe Dia(12Ø 1.0t)
Pressure
(㎏/㎠)