fb2t-000z IDEC Corporation, fb2t-000z Datasheet - Page 6

no-image

fb2t-000z

Manufacturer Part Number
fb2t-000z
Description
Fb Series Plastic Control Boxes
Manufacturer
IDEC Corporation
Datasheet
6
FB
Installing the Cable Gland
• Break a desired knockout to mount a cable gland
Installing the Cover and Base
• Attach the cover to the base so that the TOP mark on the cover
• Use cover mounting screws
Applicable Crimping Terminal
HW/TW Series
Non-insulated Terminal
XW Series (Screw Terminal Type
Applicable Cable Gland
• Use cable glands with waterproof
1. When using flexible conduit and
• Applicable Flexible Conduit Example: Type VF-03 (Nihon Flex)
Non-insulated Terminal
3.0 max.
6.0 max.
Gland Port Size
using a hammer and a screwdriver, and install the
cable gland.
∗ When breaking the knockout to make a cable gland hole,
∗ Note that cracks or burrs on the cable gland hole will
and base are in the same direction.
to attach the cover to the
base. (Recommended tight-
ening torque: 1.3±0.1 N·m)
∗ Make sure that the cover and
∗ When a spade terminal is used, the dimension is 4.7 to 5.9 mm.
∗ Be sure to install an insulating tube on the crimping terminal.
∗ When using crimping terminals for the XW series, use only one crimping
∗ Make sure that the wiring does not contact the FB series.
characteristics (IP65, TYPE 4X)
which can be mounted on a panel
thickness of 3 mm or more.
∗ Locking nuts are not attached.
Instructions
metal cable gland.
be careful not to damage the internal contact block.
degrade the waterproof characteristics.
the base are attached in the
correct direction. Otherwise,
the FB series may be dam-
aged.
terminal for each terminal.
4.0 max.
PG13.5
G1/2
M20
Series
W
14.9 max.
ø3.2 min.
B
B
ø3.6 min.
Plastic Cable Gland
4.7 min.
(Note)
A
Applicable Crimping Terminal
A
6.0 min.
Plastic Control Boxes
Applicable Crimping Terminal
A
A
18.3 max.
B
B
20.2 max.
W dimensions
Direction of A: 8.0 maximum
Direction of B: 6.6 maximum
Insulating Tube
(Cover)
4.7 to 5.9
TOP
RLC-103EC20 (Nihon Flex)
RLC-103 (Nihon Flex)
RBC-103PG13.5 (Nihon Flex)
Wire
Insulating Tube
   
Wire
6.0 max.
3.0 max.
Metal Cable Gland
M20. G1/2
PG13.5
4.0 max.
Marking
10 mm max.
TOP
All dimensions in mm.
W
Insulated Terminal
Insulated Terminal
14.9 max.
ø3.2 min.
20.2 max
ø3.6 min.
(Base)
6.0 min.
TOP
4.7 to 5.9
30 mm
max.
2. When using plastic cable gland, metal cable gland and multi-core
3. Locking nut for installing the cable gland
• Tighten cable glands to a torque of 3.0±0.3 N·m.
• Determine the cable gland for a multi-core cable according to the
• When wiring from the back of FB series, use the ø14 knockout on
Notes
Applicable Wire Size
• Determine the wire size in consideration of the applicable wire for
Wiring
• Avoid foreign objects such as dust, liquid, and oil from entering the
• Do not twist or pull the cable of flexible conduit with excessive
• Because the FB series is not provided with a PG terminal, bond-
Installation of control units on 30mm centers
• When mounting HW/TW series control units
Operation
• Avoid any contact with oil or coolants.
• Use the FB series for INDOOR applications only.
Contact Cover Box
Specifications, applicable units, and wiring
• Same as the standard control boxes.
Installing XW series control units to the FB1WR-111Z
contact cover
• Remove the contact block and the locking ring from the operator
• Attach the contact block to the operator. After wiring, attach the
• Use a nameplate if necessary.
Gland Port Size
∗ Insufficient tightening of the cable gland may degrade the waterproof
∗ Electric shock protection Class II is maintained only when a plastic cable
outside diameter of the cable sheath.
the back of the control box. A cable gland cannot be installed to
the ø14 knockout.
control units and the applicable diameter of cables.
switch while connecting a conduit or wiring.
force. Otherwise, the wire, FB series, and control units may be
damaged.
ing circuits cannot be interconnected.
on 30mm mounting centers (close mounting),
make sure to use a barrier (optional: HW-
VG1) to secure the insulation properties of the
terminal. The barriers (HW-VG1) can be eas-
ily pressed into the side of the contact block.
Otherwise, the control box may be damaged.
and check that the rubber gasket is in place. Insert the operator
from panel front into the panel hole. Attach the rubber gasket and
the base to the operator unit (place the rubber gasket between the
panel and the base) and tighten the locking ring using locking ring
wrench MW9Z-T1. Recommended tightening torque: 2.0 N·m
cover to the base using four cover mounting screws. Recom-
mended tightening torque:1.3±0.1 N·m
cable
characteristics.
gland is used. When using metallic cable glands, install a proper ground-
ing provision or use only one cable gland.
PG13.5
Gland Port Size
G1/2
M20
PG13.5
G1/2
M20
5311 1220 [Skintop-ST-M]
Applicable gasket: GPM20
(LAPP, Germany)
5380 6030 [Skintop-ST-PF]
Applicable gasket: GP 050
(LAPP, Germany)
5301 5030 [Skintop-ST]
Applicable gasket: GP13.5
(LAPP, Germany)
Plastic Cable Gland
Locking Nut Type No. (made of plastic)
HW9Z-NM20 (IDEC)
HW9Z-G (IDEC)
HW9Z-PG135 (IDEC)
ALS- ∗∗ EC20 (Nihon Flex)
ALS16- ∗∗ (Nihon Flex)
ABS- ∗∗ PG13.5 (Nihon Flex)
Metal Cable Gland
Barrier
(optional, HW-VG1)
30
(06/07/04)