Reset Modify-Read
This instruction stops the automatic increment of the column address by the read display data instruction, but
the column address is still increased by the write display data instruction. And it reduces the load of
microprocessor when the data of a specific area is repeatedly changed during cursor blinking or others. This
mode is canceled by the reset Modify-read instruction.
This instruction cancels the Modify-read mode, and makes the column address return to its initial value just
before the set Modify-read instruction is started.
RS
RS
0
0
PRELIMINARY SPEC. VER. 1.1
RW
RW
0
0
NO
DB7
DB7
1
1
Figure 25. Sequence for Cursor Display
Return Column Address (N)