ADE7518
Active Energy Pulse Output
All of the ADE7518 circuitry has a pulse output whose frequency is
proportional to active power (see the Active Power Calculation
section). This pulse frequency output uses the calibrated signal
from the WGAIN register output, and its behavior is consistent
with the setting of the active energy accumulation mode in the
ACCMODE register (0x0F). The pulse output is active low and
should be preferably connected to an LED, as shown in Figure 66.
ACTIVE ENERGY
ACTIVE POWER
Figure 55. Energy Accumulation in Watt-Absolute Accumulation Mode
APSIGN FLAG
THRESHOLD
THRESHOLD
NO LOAD
NO LOAD
FROM VOLTAGE
APNOLOAD
CHANNEL
INTERRUPT STATUS REGISTERS
OUTPUT
FROM
LPF2
ADC
WATTOS[15:0]
LPF1
POS
WGAIN[11:0]
NEG
ZERO-CROSSING
DETECTION
POS
Figure 56. Line Cycle Active Energy Accumulation
DIGITAL-TO-FREQUENCY
APNOLOAD
CONVERTER
WDIV[7:0]
%
TO
CALIBRATION
LINCYC[15:0]
Rev. 0 | Page 52 of 128
CONTROL
+
+
Line Cycle Active Energy Accumulation Mode
In line cycle active energy accumulation mode, the energy
accumulation of the ADE7518 can be synchronized to the
voltage channel zero crossing so that active energy can be
accumulated over an integer number of half-line cycles. The
advantage of summing the active energy over an integer number
of line cycles is that the sinusoidal component in the active energy
is reduced to 0. This eliminates any ripple in the energy calculation.
Energy is calculated more accurately and more quickly because
the integration period can be shortened. By using this mode,
the energy calibration can be greatly simplified, and the time
required to calibrate the meter can be significantly reduced.
In line cycle active energy accumulation mode, the ADE7518
accumulates the active power signal in the LWATTHR register
for an integral number of line cycles, as shown in Figure 56. The
number of half-line cycles is specified in the LINCYC register.
The ADE7518 can accumulate active power for up to 65,535
half-line cycles. Because the active power is integrated on an
integer number of line cycles, the CYCEND flag in the Interrupt
Status 3 SFR (MIRQSTH, 0xDE) is set at the end of an active
energy accumulation line cycle. If the CYCEND enable bit in
the Interrupt Enable 3 SFR (MIRQENH, 0xDB) is set, the 8052
core has a pending ADE interrupt. The ADE interrupt stays
active until the CYCEND status bit is cleared (see the Energy
Measurement Interrupts section). Another calibration cycle
starts as soon as the CYCEND flag is set. If the LWATTHR
register is not read before a new CYCEND flag is set, the
LWATTHR register is overwritten by a new value.
48
23
LWATTHR[23:0]
0
ACTIVE ENERGY
IS ACCUMULATED IN
THE INTERNAL REGISTER,
AND THE LWATTHR
REGISTER IS UPDATED
AT THE END OF THE LINCYC
HALF-LINE CYCLES
0