adm1027 Analog Devices, Inc., adm1027 Datasheet - Page 29

no-image

adm1027

Manufacturer Part Number
adm1027
Description
Dbcool? Remote Thermal Controller And Voltage Monitor
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adm1027-SI
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQZ
Manufacturer:
AD
Quantity:
8 852
Part Number:
adm1027RQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027S1RO
Manufacturer:
AD
Quantity:
72
Part Number:
adm1027S1RO
Manufacturer:
XILINX
Quantity:
86
Part Number:
adm1027S1RQZ
Manufacturer:
RICOH
Quantity:
2 305
Step 2
Configuring the Mux: Which Temperature Controls Which Fan?
Having decided on the system hardware configuration, the fans
can be assigned to particular temperature channels. Not only
can fans be assigned to individual channels, but how a fan
behaves is configurable. For example, fans can run under
automatic fan control, manually (software control), or can run
at the fastest speed calculated by multiple temperature channels.
The MUX is the bridge between temperature measurement
channels and the three PWM outputs.
Bits <7:5> (BHVR bits) of Registers 0x5C, 0x5D, and 0x5E
(PWM configuration registers) control the behavior of the fans
connected to the PWM1, PWM2, and PWM3 outputs. The
values selected for these bits determine how the MUX connects
a temperature measurement channel to a PWM output.
REV. A
AMBIENT TEMP
REMOTE 1 =
REMOTE 2 =
VRM TEMP
CPU TEMP
LOCAL =
T
T
T
MIN
MIN
MIN
THERMAL CALIBRATION
THERMAL CALIBRATION
THERMAL CALIBRATION
Figure 28. Assigning Temperature Channels to Fan Channels
T
T
T
RANGE
RANGE
RANGE
100%
100%
0%
100%
0%
0%
MUX
MUX
–29–
PWM
PWM
PWM
Automatic Fan Control Mux Options
<7:5> (BHVR) REGISTERS 0x5C, 0x5D, 0x5E
000 = Remote 1 temp controls PWMx
001 = Local temp controls PWMx
010 = Remote 2 temp controls PWMx
101 = Fastest speed calculated by local and remote 2 temp
controls PWMx
110 = Fastest speed calculated by all three temperature channels
controls PWMx
The fastest speed calculated options refer to the ability to con-
trol one PWM output based on multiple temperature channels.
While the thermal characteristics of the three temperature zones
can be set up differently, they can drive a single fan. An example
would be if the fan turns on when Remote 1 temp exceeds 60∞C
or local temp exceeds 45∞C.
Other Mux Options
<7:5> (BHVR) REGISTERS
011 = PWMx runs full-speed (default).
100 = PWMx disabled.
111 = Manual Mode. PWMx is run under software control. In
this mode, PWM duty cycle registers (Reg. 0x30 to 0x32) are
writable and control the PWM outputs.
MIN
MIN
MIN
TACHOMETERS 3
MEASUREMENT
TACHOMETER 1
TACHOMETER 2
ENHANCEMENT
MEASUREMENT
ENHANCEMENT
MEASUREMENT
ENHANCEMENT
(ACOUSTIC
(ACOUSTIC
(ACOUSTIC
CONTROL
CONTROL
CONTROL
AND 4
RAMP
RAMP
RAMP
GENERATOR
GENERATOR
GENERATOR
CONFIG
CONFIG
CONFIG
PWM
PWM
PWM
PWM
PWM
PWM
0x5C, 0x5D, 0x5E
PWM1
TACH1
PWM2
TACH2
PWM3
TACH3
ADM1027
CPU
FANSINK
FRONT
CHASSIS
REAR
CHASSIS

Related parts for adm1027