adm1027 Analog Devices, Inc., adm1027 Datasheet - Page 49

no-image

adm1027

Manufacturer Part Number
adm1027
Description
Dbcool? Remote Thermal Controller And Voltage Monitor
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adm1027-SI
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQZ
Manufacturer:
AD
Quantity:
8 852
Part Number:
adm1027RQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027S1RO
Manufacturer:
AD
Quantity:
72
Part Number:
adm1027S1RO
Manufacturer:
XILINX
Quantity:
86
Part Number:
adm1027S1RQZ
Manufacturer:
RICOH
Quantity:
2 305
Bit
<2:0>
<3>
<6:4>
<7>
This register becomes read-only when the Configuration Register 1 lock bit is set to 1. Any further attempts to write to this register
will have no effect.
REV. A
Name
ACOU3
EN3
ACOU2
EN2
Table XIX. Register 0x63 – Enhance Acoustics Register 2 (Power-On Default = 0x00)
R/W
Read/Write
Read/Write
Read/Write
Read/Write
Description
These bits select the ramp rate applied to the PWM3 output. Instead of PWM3 jumping
instantaneously to its newly calculated speed, PWM3 will ramp gracefully at the rate
determined by these bits. This effect enhances the acoustics of the fan being driven by the
PWM3 output.
Time slot increase
000 = 1
001 = 2
010 = 3
011 = 5
100 = 8
101 = 12
110 = 24
111 = 48
When this bit is 1, acoustic enhancement is enabled on PWM3 output. When acoustic
enhancement is enabled, fan spin-up time should be disabled.
These bits select the ramp rate applied to the PWM2 output. Instead of PWM2 jumping
instantaneously to its newly calculated speed, PWM2 will ramp gracefully at the rate
determined by these bits. This effect enhances the acoustics of the fans being driven by
the PWM2 output.
Time slot increase
000 = 1
001 = 2
010 = 3
011 = 5
100 = 8
101 = 12
110 = 24
111 = 48
When this bit is 1, acoustic enhancement is enabled on PWM2 output. When acoustic
enhancement is enabled, fan spin-up time should be disabled.
–49–
Time for 33% to 100%
35 sec
17.6 sec
11.8 sec
7 sec
4.4 sec
3 sec
1.6 sec
0.8 sec
Time for 33% to 100%
35 sec
17.6 sec
11.8 sec
7 sec
4.4 sec
3 sec
1.6 sec
0.8 sec
ADM1027