adm1027 Analog Devices, Inc., adm1027 Datasheet - Page 30
adm1027
Manufacturer Part Number
adm1027
Description
Dbcool? Remote Thermal Controller And Voltage Monitor
Manufacturer
Analog Devices, Inc.
Datasheet
1.ADM1027.pdf
(56 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adm1027-SI
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm1027ARQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
adm1027ARQZ
Manufacturer:
AD
Quantity:
8 852
Part Number:
adm1027RQ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
adm1027S1RO
Manufacturer:
AD
Quantity:
72
Company:
Part Number:
adm1027S1RO
Manufacturer:
XILINX
Quantity:
86
Company:
Part Number:
adm1027S1RQZ
Manufacturer:
RICOH
Quantity:
2 305
ADM1027
Step 3
Determine T
T
under automatic fan control. The speed at which the fan runs
at T
temperature channel specific, e.g., 25∞C for ambient channel,
30∞C for VRM temperature, and 40∞C for processor temperature.
T
grammed in 1∞C increments. There is a T
with each temperature measurement channel, Remote 1, Local
and Remote 2 Temp. Once the T
turns on and runs at minimum PWM duty cycle. The fan will
turn off once temperature has dropped below T
(detailed later).
To overcome fan inertia, the fan is spun up until two valid TACH
rising edges are counted. See the Fan Start-Up Timeout section
for more details. In some cases, primarily for psycho-acoustic
reasons, it is desirable that the fan never switches off below T
Bits <7:5> of Enhance Acoustics Register 1 (Reg. 0x62), when
set, keep the fans running at PWM minimum duty cycle should
the temperature be below T
MIN
MIN
MIN
is the temperature at which the fans will start to turn on
is an 8-bit twos complement value that can be pro-
is programmed later. The T
MIN
AMBIENT TEMP
REMOTE 2 =
REMOTE 1 =
Setting for Each Thermal Channel
VRM TEMP
CPU TEMP
LOCAL =
100%
0%
MIN
T
T
T
MIN
MIN
MIN
.
THERMAL CALIBRATION
THERMAL CALIBRATION
THERMAL CALIBRATION
MIN
T
MIN
MIN
value is exceeded, the fan
values chosen will be
MIN
T
T
T
RANGE
RANGE
RANGE
Figure 29. Understanding T
register associated
100%
MIN
100%
0%
100%
0%
0%
– T
HYST
MUX
MIN
.
–30–
PWM
PWM
PWM
T
Reg. 0x67 Remote 1 Temperature T
Reg. 0x68 Local Temperature T
Reg. 0x69 Remote 2 Temperature T
Enhance Acoustics Reg 1 (Reg. 0x62)
Bit 7 (MIN3) = 0, PWM3 is OFF (0% PWM duty cycle) when
temperature is below T
Bit 7 (MIN3) = 1, PWM3 runs at PWM3 minimum duty cycle
below T
Bit 6 (MIN2) = 0, PWM2 is OFF (0% PWM duty cycle) when
temperature is below T
Bit 6 (MIN2) = 1, PWM2 runs at PWM2 minimum duty cycle
below T
Bit 5 (MIN1) = 0, PWM1 is OFF (0% PWM duty cycle) when
temperature is below T
Bit 5 (MIN1) = 1, PWM1 runs at PWM1 minimum duty cycle
below T
MIN
MIN
MIN
MIN
MIN
Registers
TACHOMETERS 3
MEASUREMENT
ENHANCEMENT
TACHOMETER 1
MEASUREMENT
ENHANCEMENT
TACHOMETER 2
MEASUREMENT
ENHANCEMENT
(ACOUSTIC
(ACOUSTIC
(ACOUSTIC
CONTROL
CONTROL
CONTROL
MIN
MIN
MIN
AND 4
Parameter
RAMP
RAMP
RAMP
– T
– T
– T
HYST
HYST
HYST
GENERATOR
GENERATOR
GENERATOR
.
.
.
CONFIG
CONFIG
CONFIG
PWM
PWM
PWM
PWM
PWM
PWM
MIN
MIN
MIN
– T
– T
– T
HYST
HYST
HYST
PWM1
TACH1
PWM2
TACH2
PWM3
TACH3
MIN
.
.
.
= 0x5A (90∞C default)
MIN
MIN
= 0x5A (90∞C default)
= 0x5A (90∞C default)
CPU
FANSINK
FRONT
CHASSIS
REAR
CHASSIS
REV. A