mc9s12xs128 Freescale Semiconductor, Inc, mc9s12xs128 Datasheet - Page 430

no-image

mc9s12xs128

Manufacturer Part Number
mc9s12xs128
Description
Hcs12 Microcontrollers 16-bit Automotive Microcontroller
Manufacturer
Freescale Semiconductor, Inc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mc9s12xs128CAA
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s12xs128CAA
Quantity:
37
Part Number:
mc9s12xs128CAE
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s12xs128CAL
Manufacturer:
FREESCALE
Quantity:
3 050
Part Number:
mc9s12xs128CAL
Manufacturer:
FREESCALE
Quantity:
3 050
Part Number:
mc9s12xs128CAL
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s12xs128MAA
Manufacturer:
FREESCALE
Quantity:
4 000
Part Number:
mc9s12xs128MAA
Manufacturer:
FREESCALE
Quantity:
5 630
Part Number:
mc9s12xs128MAA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
mc9s12xs128MAA
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s12xs128MAA
0
Part Number:
mc9s12xs128MAA 1M04M
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
mc9s12xs128MAE
Manufacturer:
INITIO
Quantity:
3 310
Part Number:
mc9s12xs128MAL
Manufacturer:
FREESCALE
Quantity:
20 000
Company:
Part Number:
mc9s12xs128VAA
Quantity:
58
Serial Communication Interface (S12SCIV5)
14.4.6.6.1
In this wakeup method, an idle condition on the RXD pin clears the RWU bit and wakes up the SCI. The
initial frame or frames of every message contain addressing information. All receivers evaluate the
addressing information, and receivers for which the message is addressed process the frames that follow.
Any receiver for which a message is not addressed can set its RWU bit and return to the standby state. The
RWU bit remains set and the receiver remains on standby until another idle character appears on the RXD
pin.
Idle line wakeup requires that messages be separated by at least one idle character and that no message
contains idle characters.
The idle character that wakes a receiver does not set the receiver idle bit, IDLE, or the receive data register
full flag, RDRF.
The idle line type bit, ILT, determines whether the receiver begins counting logic 1s as idle character bits
after the start bit or after the stop bit. ILT is in SCI control register 1 (SCICR1).
14.4.6.6.2
In this wakeup method, a logic 1 in the most significant bit (MSB) position of a frame clears the RWU bit
and wakes up the SCI. The logic 1 in the MSB position marks a frame as an address frame that contains
addressing information. All receivers evaluate the addressing information, and the receivers for which the
message is addressed process the frames that follow.Any receiver for which a message is not addressed can
set its RWU bit and return to the standby state. The RWU bit remains set and the receiver remains on
standby until another address frame appears on the RXD pin.
The logic 1 MSB of an address frame clears the receiver’s RWU bit before the stop bit is received and sets
the RDRF flag.
Address mark wakeup allows messages to contain idle characters but requires that the MSB be reserved
for use in address frames.
14.4.7
Normally, the SCI uses two pins for transmitting and receiving. In single-wire operation, the RXD pin is
disconnected from the SCI. The SCI uses the TXD pin for both receiving and transmitting.
430
Single-Wire Operation
Idle Input line Wakeup (WAKE = 0)
Address Mark Wakeup (WAKE = 1)
With the WAKE bit clear, setting the RWU bit after the RXD pin has been
idle can cause the receiver to wake up immediately.
Figure 14-30. Single-Wire Operation (LOOPS = 1, RSRC = 1)
Transmitter
Receiver
S12XS Family Reference Manual, Rev. 1.10
NOTE
RXD
TXD
Freescale Semiconductor