ata5279n ATMEL Corporation, ata5279n Datasheet - Page 13

no-image

ata5279n

Manufacturer Part Number
ata5279n
Description
Antenna Driver For Multiple Antennas
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATA5279N
Manufacturer:
ATMEL
Quantity:
1 980
Part Number:
ATA5279N
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Table 3-2.
3.7
9125C–RKE–01/09
Step
1
2
3
4
5
6
7
8
SPI
Get Driver Setup
Get Driver Setup
Get Driver Setup
Sequence for Example 2, Using the Diagnosis Mode
Set Coil Current
Set Coil Current
- no command -
- no command -
Select Driver
Command
Again, this is only an example of how the diagnosis system can be used. Generally, a more sys-
tematic approach is suggested in order to efficiently test all connection lines used.
Note:
The SPI is used to select the required coil and its current, to provide LF data to the IC, to select
and start an LF transmission, and to read out status information. It is equipped with a chip select
input to enable or disable communication. When disabled, the data output of the IC is in high
impedance mode, so other devices may communicate on the same bus.
The interface is configured as a slave device, always requiring a master (e.g., a microcontroller)
for operation. The maximum input clock frequency is 1/4 of the system clock present at the OSCI
pin, resulting, for example, in a maximum signal speed of 2 Mbit/s when using a typical 8 MHz
input clock. The SPI features four different operation modes, which only differ in the relationship
between the clock signal (S_CLK) and the data I/Os.
Both the SPI itself and the corresponding I/O lines are supplied by the application-provided logic
supply voltage connected to the VIF pin. This ensures that the controller (master) and the IC
(slave) operate with the same voltage levels.
In total, four modes of operations are possible, each differing in clock polarity and phase.
3-7
and
To exit the diagnosis mode correctly, two SPI commands have to be sent: the first is the Select
Driver command with the DM bit set to 0 and the second is a Reset Fault Status command. See
also SPI Command Description.
Figure 3-8
I/O
O
O
O
I
I
I
I
I
I
illustrate this.
00101101 – 2Dh
00011101 – 1Dh
10100010 – A2h
10100000 – A0h
01101000 – 68h
00011101 – 15h
01101000 – 68h
01101000 – 68h
00010101 – 15h
Coding
Actions / Remarks
Selects driver 4 with Diagnosis Mode enabled
Reads back active driver info:
Channel 4 active, A4N returns a 1
Closes test switches S_L4P and S_H4N
Note:
Wait for the test structures to stabilize in the new setting, see
first example
Reads back active driver info:
Channel 4 active, both lines return a 1
Closes test switches S_L4P and S_L4N
Note:
Wait for the test structures to stabilize in the new setting, see
first example
Reads back active driver info:
Channel 4 active and A4N returns a 1
S_H4P and S_L4N are open then
S_H4P and S_H4N are open then
ATA5279N [Preliminary]
Figure
13

Related parts for ata5279n