ak4342 AKM Semiconductor, Inc., ak4342 Datasheet - Page 30

no-image

ak4342

Manufacturer Part Number
ak4342
Description
24-bit Stereo Dac With Hp-amp & 2v Line-out
Manufacturer
AKM Semiconductor, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ak4342EN
Manufacturer:
SILICON
Quantity:
231
Company:
Part Number:
ak4342EN-L
Quantity:
1 100
ASAHI KASEI
2. I
The AK4342 supports a fast-mode I
1. WRITE Operations
Figure 22 shows the data transfer sequence for the I
HIGH to LOW transition on the SDA line while SCL is HIGH indicates a START condition (Figure 28). After the
START condition, a slave address is sent. This address is 7 bits long followed by an eighth bit that is a data direction bit
(R/W). The most significant five bits of the slave address are fixed as “001000”. The next one bit is CAD0 (device address
bit). This bit identifies the specific device on the bus. The hard-wired input pin (CAD0 pin) set these device address bits
(Figure 23). If the slave address matches that of the AK4342, the AK4342 generates an acknowledge and the operation is
executed. The master must generate the acknowledge-related clock pulse and release the SDA line (HIGH) during the
acknowledge clock pulse (Figure 29). A R/W bit value of “1” indicates that the read operation is to be executed. A “0”
indicates that the write operation is to be executed.
The second byte consists of the control register address of the AK4342. The format is MSB first, and those most
significant 3-bits are fixed to zeros (Figure 24). The data after the second byte contains control data. The format is MSB
first, 8bits (Figure 25). The AK4342 generates an acknowledge after each byte has been received. A data transfer is
always terminated by a STOP condition generated by the master. A LOW to HIGH transition on the SDA line while SCL
is HIGH defines a STOP condition (Figure 28).
The AK4342 can perform more than one byte write operation per sequence. After receipt of the third byte the AK4342
generates an acknowledge and awaits the next data. The master can transmit more than one byte instead of terminating the
write cycle after the first data byte is transferred. After receiving each data packet the internal 5-bit address counter is
incremented by one, and the next data is automatically taken into the next address. If the address exceeds 09H prior to
generating the stop condition, the address counter will “roll over” to 00H and the previous data will be overwritten.
The data on the SDA line must remain stable during the HIGH period of the clock. The HIGH or LOW state of the data
line can only change when the clock signal on the SCL line is LOW (Figure 30) except for the START and STOP
conditions.
MS0506-E-02
2
C-bus Control Mode (I2C pin = “H”)
SDA
S
T
A
R
T
S
Slave
Address
D7
0
0
R/W="0"
Figure 22. Data Transfer Sequence at the I
C
A
K
D6
0
0
2
Figure 25. Byte Structure after the second byte
C-bus system (max: 400kHz).
Sub
Address(n)
D5
1
0
Figure 24. The Second Byte
Figure 23. The First Byte
A
C
K
2
C-bus mode. All commands are preceded by a START condition. A
Data(n)
A4
D4
0
- 30 -
C
A
K
A3
D3
0
Data(n+1)
2
A2
D2
C-Bus Mode
0
A
C
K
CAD0
A1
D1
C
A
K
Data(n+x)
R/W
A0
D0
A
C
K
S
T
O
P
P
[AK4342]
2006/07

Related parts for ak4342