sp3222ebey-tr Exar Corporation, sp3222ebey-tr Datasheet - Page 13

no-image

sp3222ebey-tr

Manufacturer Part Number
sp3222ebey-tr
Description
Sp3232eb -true +3.0v To +5.5v Rs-232 Transceivers
Manufacturer
Exar Corporation
Datasheet
Date:11/02/05
Figure 18. ESD Test Circuit for Human Body Model
The Contact Discharge Method applies the ESD
current directly to the EUT. This method was
devised to reduce the unpredictability of the
ESD arc. The discharge current rise time is
constant since the energy is directly transferred
without the air-gap arc. In situations such as
hand held systems, the ESD charge can be
directly discharged to the equipment from a
person already holding the equipment. The
current is transferred on to the keypad or the
serial port of the equipment directly and then
travels through the PCB and finally to the IC.
Date: 02/27/05
Figure 19. ESD Test Circuit for IEC1000-4-2
DC Power
Source
DC Power
Source
R
R
C
C
SP3222EB/SP3232EB True +3.0V to +5.5V RS-232 Transceivers
SP3222EB/3232EB True +3.0 to +5.5V RS-232 Transceivers
R
R
C
C
SW1
SW1
SW1
SW1
C
C
13
S
13
S
C
C
The circuit models in Figures 18 and 19
represent the typical ESD testing circuits used
for all three methods. The C
with the DC power supply when the first
switch (SW1) is on. Now that the capacitor is
charged, the second switch (SW2) is on while
SW1 switches off. The voltage stored in the
capacitor is then applied through R
limiting resistor, onto the device under test
(DUT). In ESD tests, the SW2 switch is pulsed
so that the device under test receives a duration
of voltage.
R S and R V add up to 330
R S and R V add up to 330
S
S
R
R
S
S
R
R
Contact-Discharge Module
Contact-Discharge Module
S
S
R
R
V
V
SW2
SW2
for IEC1000-4-2.
for IEC1000-4-2.
© Copyright 2005 Sipex Corporation
SW2
SW2
© Copyright 2005 Sipex Corporation
S
is initially charged
Device
Under
Test
S
, the current
Device
Under
Test

Related parts for sp3222ebey-tr