71m6534h-igt Maxim Integrated Products, Inc., 71m6534h-igt Datasheet - Page 17

no-image

71m6534h-igt

Manufacturer Part Number
71m6534h-igt
Description
Energy Meter Ic
Manufacturer
Maxim Integrated Products, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71m6534h-igt/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71m6534h-igtR/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
FDS_6533_6534_004
1.2.14 CE Functional Overview
The ADC processes one sample per channel per multiplexer cycle.
samples taken during one multiplexer cycle (phases A, B, and C being processed). During an ALT mul-
tiplexer sequence, missing samples are filled in by the CE.
The number of samples processed during one accumulation cycle is controlled by the I/O RAM registers
PRE_SAMPS (0x2001[7:6]) and SUM_CYCLES (0x2001[5:0]). The integration time for each energy output is:
For example, PRE_SAMPS = 42 and SUM_CYCLES = 50 will establish 2100 samples per accumulation
cycle. PRE_SAMPS = 100 and SUM_CYCLES = 21 will result in the exact same accumulation cycle of 2100
samples or 833 ms. After an accumulation cycle is completed, the XFER_BUSY interrupt signals to the
MPU that accumulated data are available.
The end of each multiplexer cycle is signaled to the MPU by the CE_BUSY interrupt. At the end of each
multiplexer cycle, status information, such as sag data and the digitized input signal, is available to the MPU.
Figure 6
sisting of 2100 samples of 397µs each, followed by the XFER_BUSY interrupt. The sampling in this ex-
ample is applied to a 50 Hz signal.
v1.1
PRE_SAMPS * SUM_CYCLES / 2520.6, where 2520.6 is the sample rate in Hz
shows the accumulation interval resulting from PRE_SAMPS = 42 and SUM_CYCLES = 50, con-
20ms
B
B
IA
IA
1/2520.6Hz = 397µs
1/2520.6Hz = 397µs
© 2007-2009 TERIDIAN Semiconductor Corporation
Figure 5: Samples from Multiplexer Cycle
VA
VA
VB
VB
IB
IB
Figure 6: Accumulation Interval
IC
IC
VC
VC
833ms
13/32768Hz = 397µs
13/32768Hz = 397µs
per mux cycle
per mux cycle
2/32768Hz =
2/32768Hz =
61.04µs
61.04µs
A
A
Figure 5
C
C
71M6533/71M6534 Data Sheet
shows the timing of the
Interrupt to MPU
XFER_BUSY
17

Related parts for 71m6534h-igt