ic42s16400 ETC-unknow, ic42s16400 Datasheet - Page 14

no-image

ic42s16400

Manufacturer Part Number
ic42s16400
Description
1m X 16bit X 4 Banks 64-mbit Sdram
Manufacturer
ETC-unknow
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ic42s16400-6T
Manufacturer:
ICSI
Quantity:
3 500
Part Number:
ic42s16400-6T
Manufacturer:
ICSI
Quantity:
3 500
Part Number:
ic42s16400-6T
Manufacturer:
ST
Quantity:
3 000
Part Number:
ic42s16400-6T
Manufacturer:
TSOP
Quantity:
4 800
Part Number:
ic42s16400-6T
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
ic42s16400-6TG
Manufacturer:
ICSI
Quantity:
1 080
Part Number:
ic42s16400-6TG
Manufacturer:
ICSI
Quantity:
1 000
Part Number:
ic42s16400-7BG
Manufacturer:
ICSI/PBF
Quantity:
2 685
Part Number:
ic42s16400-7T
Manufacturer:
ICSI
Quantity:
1 000
Part Number:
ic42s16400-7TG
Manufacturer:
ST
0
Company:
Part Number:
ic42s16400-7TG
Quantity:
14
Part Number:
ic42s16400-7TIG
Manufacturer:
ICSI
Quantity:
1 000
Company:
Part Number:
ic42s16400D-6TL
Quantity:
20
IC42S16400
CKE RELATED COMMAND TRUTH TABLE
14
Current State
Self-Refresh (S.R.)
Self-Refresh Recovery
Power-Down (P.D.)
Both Banks Idle
Any state
other than
listed above
Notes:
1. H : Hight level, L : low level, X : High or low level (Don’t care).
2. CKE Low to High transition will re-enable CLK and other inputs asynchronously. A minimum setup time must be satisfied
3. Power down and Self refresh can be entered only from the both banks idle state.
4. Must be legal command as defined in Operative Command Table.
5. Illegal if t
before any command other than EXIT.
SREX
is not satisfied.
Operation
INVALID, CLK (n - 1)would exit S.R.
Self-Refresh Recovery
Self-Refresh Recovery
Illegal
Illegal
Maintain S.R.
Idle After t
Idle After t
Illegal
Illegal
Begin clock suspend next cycle
Begin clock suspend next cycle
Illegal
Illegal
Exit clock suspend next cycle
Maintain clock suspend
INVALID, CLK (n - 1) would exit P.D.
EXIT P.D. -> Idle
Maintain power down mode
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Auto-Refresh
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Self-Refresh
Refer to operations in Operative Command Table
Power-Down
Refer to operations in Operative Command Table
Begin clock suspend next cycle
Exit clock suspend next cycle
Maintain clock suspend
RC
RC
(3)
(3)
(2)
(2)
(2)
(2)
(5)
(5)
(4)
(1)
n-1
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
L
L
L
L
L
L
L
L
L
L
L
L
CKE
X
H
H
H
H
H
H
H
H
H
X
H
H
H
H
H
H
X
H
H
n
L
L
L
L
L
L
L
L
L
L
L
L
L
L
CS
CS
CS
CS
CS
H
H
H
H
H
X
L
L
L
X
L
L
L
L
L
L
X
X
X
X
X
L
L
L
L
L
L
L
L
X
X
X
X
X
Integrated Circuit Solution Inc.
RAS
RAS
RAS
RAS
RAS
H
H
H
H
H
H
H
H
X
X
L
X
X
L
X
L
X
X
X
X
X
X
L
L
L
X
L
L
L
X
X
X
X
X
CAS
CAS
CAS
CAS
CAS
X
X
H
X
X
X
H
X
X
H
X
X
X
X
X
X
X
X
H
X
X
H
X
X
X
X
X
L
L
L
L
L
L
L
WE
WE
WE
WE
WE
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
H
X
X
X
H
X
X
X
X
X
L
L
DR034-0E 12/02/2003
Address
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Op - Code
X
Op - Code
X
X
X
X
X

Related parts for ic42s16400