hb28j128mm3 Renesas Electronics Corporation., hb28j128mm3 Datasheet - Page 68

no-image

hb28j128mm3

Manufacturer Part Number
hb28j128mm3
Description
Multimediacard 32 Mbyte/64 Mbyte/128 Mbyte/256 Mbyte/512 Mbyte
Manufacturer
Renesas Electronics Corporation.
Datasheet
HB28K032/L064/J128/J256/J512MM3, HB28K032/L064/J128/J256RM3
Clearing Status Bits
As described in the previous paragraphs, in SPI mode, status bits are reported to the host in three different
formats: response R1, response R2 and data error token (the same bits may exist in multiple response
types
As in the MultiMediaCard mode, error bits are cleared when read by the host, regardless of the response
format. State indicators are either cleared by reading or in accordance with the card state. All Error/Status
bits defined in MultiMediaCard mode, with the exception of underrun and overrun, have the same meaning
and usage in SPI mode. The following table summarizes the set and clear conditions for the various status
bits:
SPI mode Status bits
Identifier
Out of range
Address error
Erase sequence
error
Error param
Parameter error
WP violation
Com CRC error
Rev.0.02, Sep.15.2004, page 68 of 89
Type:
Clear Condition:
e.g. Card ECC failed).
command in order to read these bits.
E: Error bit.
S: Status bit.
R: Detected and set for the actual command response.
X: Detected and set during command execution. The host must poll the card by sending status
A: According to the card state.
C: Clear by read.
R1 R2
R2
Included
in resp
R2
DataErr
R1 R2
R1 R2
R2
R1 R2
Type
E R X
E R X
E R
E X
E R X
E R X
E R
Value
‘0’= no error
‘1’= error
‘0’= no error
‘1’= error
‘0’= no error
‘1’= error
‘0’= no error
‘1’= error
‘0’= no error
‘1’= error
‘0’= not protected
‘1’= protected
‘0’= no error
‘1’= error
Description
The command argument was out of
allowed range for these Renesas
MultiMediaCards.
An address which did not match the
block length was used in the
command.
An error in the sequence of erase
command sequence.
An error in the parameters of the
erase command sequence.
An error in the parameters of the
command.
Attempt to program a write protected
block.
The CRC check of the previous
command failed.
Clear
condition
C
C
C
C
C
C
C

Related parts for hb28j128mm3