Key Protect Level (kypt)
Set the key protect level.
When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the
key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. Confirm the ON/OFF status of the key-
protect switch after the H7CX is mounted to the panel.
Note: Changing mode to configuration selection mode (
KP-1 (default setting)
KP-2
KP-3
KP-4
KP-5
Note: Factory-set to OFF
(See note)
Level
OFF
Key protect indicator
ON
Meaning
No
No
No
No
No
Changing mode
(See note.)
MODE
+
1
1 s min.) or function setting mode (
Yes
Yes
Yes
Yes
No
Switching display in
run mode
Details
Yes
No
Yes
No
No
Reset key
MODE
3 s min.).
Up/down key (Up key for
Yes
Yes
No
No
No
6-digit models)