■ Settings for Advanced Functions
Settings that cannot be performed with the DIP switch are performed with the operation keys.
(See note 1.)
3s min.
Power ON
(See note 2.)
3s min.
Auto-zero
time
(AUTZ)
Startup
time
(STMR)
Key protect
level
(KYPT)
Decimal
point
position
(DP)
Prescale
value
(PSCL)
Note: 1. If the mode is switched to the function setting mode during operation, operation will
For details on operations in run mode, refer to page 54.
The characters displayed in reverse video are the initial values.
Set the key protect level with the
Set the value of each corresponding digit with the
Set the value of each corresponding digit with the
Set the value of each corresponding digit with the
Set the decimal point position using the
2. Changes made to settings in function setting mode are enabled for the first time when
(0.1s)
(0.0s)
(0.001)
(No decimal
point)
(KP-1)
continue.
the mode is changed to run mode. Also, when settings are changed, the counter is
reset (measured values initialized and output turned OFF) on returning to run mode.
(99.9s)
(999.9s)
(KP-2)
(1.000)
(One digit
after decimal
point)
(99.999)
(KP-3)
(Two digits
after decimal
point)
key.
(KP-4)
key.
(KP-5)
(Three digits
after decimal
point)
key.
key.
key.