h7cx-a11d1 Omron Corporation, h7cx-a11d1 Datasheet - Page 8

no-image

h7cx-a11d1

Manufacturer Part Number
h7cx-a11d1
Description
Multifunction Preset Counter
Manufacturer
Omron Corporation
Datasheet
Connections
■ Block Diagram
Note: All models except for H7CX-@D (models with 12 to 24-VDC power supplies) have basic insulation.
■ I/O Functions
Using as a Counter
Note: 1. In increment mode or increment/decrement mode, the present value returns to 0; in decrement mode, the present value returns to the
Using as a Tachometer
Inputs
Outputs
Inputs
Outputs
2. The reset indicator will not be lit when the total reset or reset 2 input is ON.
Input circuit
set value with 1-stage models, and returns to set value 2 with 2-stage models.
Output circuit
(Basic
insulation)
CP1, CP2
Reset or Reset 1
Total Reset or
Reset 2
(See note 2.)
OUT1, OUT2
CP1, CP2
Reset 1, Reset 2
OUT1, OUT2
Internal control
circuit
(Basic
insulation)
• In general (except for dual counter mode)
• When used as a dual counter
• In general (except for dual counter mode)
• When used as a dual counter
• When used as a 1-stage/2-stage counter
• When used as a total and preset counter
• When used as a batch counter
• When used as a dual counter
Outputs take place according to designated output mode when corresponding preset is reached.
Power supply
circuit
Reads counting signals
Increment, decrement, command, individual, and quadrature inputs accepted.
Reads CP1 count signals with CP1 input and CP2 count signals with CP2 input.
Increment signals can be input.
Resets present value and outputs (OUT2 when using the batch counter). (See note 1.)
Counting cannot be performed during reset/reset 1 input.
The reset indicator is lit during reset input.
Resets the CP1 present value (to 0).
Counting for CP1 input cannot be performed during reset 1 input.
The reset indicator is lit during reset 1 input.
Does not operate (Not used).
Resets the total count value.
Holds the total count value at 0 during total reset input.
Resets the batch count value and batch output (OUT1).
Holds the batch count value at 0 during reset 2 input.
Resets the CP2 present value.
Counting for CP2 input cannot be performed during reset 2 input.
(See note.)
Reads counting signals. (CP2 input is not available.)
Holds the measurement value and outputs. (Reset 2 input is not available.)
The reset indicator is lit during hold.
Outputs signals according to the specified output mode when a set value is reached.
Display circuit
Key switch
circuit
H7CX-A
8