2030-EUAF ALLEN-BRADLEY [Allen-Bradley], 2030-EUAF Datasheet
![no-image](/images/no-image-200.jpg)
2030-EUAF
Related parts for 2030-EUAF
2030-EUAF Summary of contents
Page 1
Safety Isolation System ElectroGuard Overview . . . . . . . . . . . . . . . . . . . . . . 12-2 Specifications . . . . . . . . . . . ...
Page 2
Safety Isolation System ElectroGuard Overview The ElectroGuard Safety Isolation System is used in place of a disconnect switch for Lockout and Tagout (LOTO). It uses power contactors and Remote Lockout Stations to accomplish LOTO. Isolating the electrical energy usually involves ...
Page 3
Principle of Operation Power Circuit 1IC 2IC Incoming 3 Phase Power Trans Control Power Grd Disconnecting Means/Branch Circuit Protection Control Circuit Remote Lockout Station Off On VDR GC Available factory installed within the ElectroGuard as ...
Page 4
Safety Isolation System ElectroGuard Non Combination Systems Power Panel Product Selection: For North America (see page 12-19 for Ordering Instructions) 3-Phase Max. Hp Rating (60Hz) Ampere Rating (AC-3) 200V 230V 460V 575V ...
Page 5
... G Catalogue Number IP 30 Enclosure IP 54 Enclosure 2030-RLSPG 2030-RLSHG Safety Isolation System ElectroGuard Non Combination Systems Type 4X Watertight Stainless Steel Enclosure 2030-RLSCW IP 54 Motor Control Centre Type Enclosure (w/bussing Enclosure 2031-!0023H 2031-C0023W 2031-!0043H 2031-C0043W 2031-!0085H 2031-C0085W 2031-!0110H ...
Page 6
Safety Isolation System ElectroGuard Combination Systems with Fusible Disconnect Switch Product Selection: For North America (see page 12-19 for Ordering Instructions) 3-Phase Max. Hp Rating (60Hz) Fuse Amp. Clip Rating 200 230 460 575 Rating/ (AC- ...
Page 7
... Combination Systems with Fusible Disconnect Switch Catalogue Number Code 208V 60Hz 240V 60Hz H A Catalogue Number Type 12 Dust tight Type 4 Watertight Painted Enclosure Steel Enclosure 2030-RLSJW 2030-RLSFW Safety Isolation System ElectroGuard 480V 60Hz 600V 60Hz B C Type 4X Watertight Stainless Steel Enclosure 2030-RLSCW 12-7 ...
Page 8
Safety Isolation System ElectroGuard Combination Systems with Fusible Disconnect Switch Product Selection for Outside of North America (see page 12-19 for Ordering Instructions) 3-Phase Max. kW Rating (50Hz) Amp. Fuse Clip Rating Rating/ (AC-3) 230V 400V 500V 600V Type 20A ...
Page 9
... Enclosure 2030-RLSWG 12-9 ...
Page 10
Safety Isolation System ElectroGuard Combination Systems with Thermal-magnetic Circuit Breaker Product Selection for North America (see page 12-19 for Ordering Instructions) 3-Phase Max. Hp Rating (60Hz) Ampere Type 1 General Rating (AC-3) 200V 230V 460V 575V ...
Page 11
Product Selection for North America (see page 12-19 for Ordering Instructions) 3-Phase Max. Hp Rating (60Hz) Ampere Type 1 General Rating (AC-3) 200V 230V 460V 575V - - 175 - 2033-A0300A - 200 - 2033-A0300A -54 300 - ...
Page 12
... B C Type 4X Watertight Stainless Steel Enclosure 2030-RLSFW 2030-RLSCW IP 54 Motor Control Centre Type Enclosure (w/bussing Enclosure 2033-!0023H -39K 2033-C0023W -39K 2033-!0023H -40K 2033-C0023W -40K 2033-!0023H -41K 2033-C0023W -41K ...
Page 13
Product Selection for Outside of North America (see page 12-19 for Ordering Instructions) 3-Phase Max. kW Rating (50Hz) Ampere Rating (AC-3) 230V 400V 500V 600V - - - 75 110 - - - 100 ...
Page 14
Safety Isolation System ElectroGuard Combination Systems with Thermal-magnetic Circuit Breaker Product Selection for Outside of North America (see page 12-19 for Ordering Instructions) 3-Phase Max. kW Rating (50Hz) Ampere Rating (AC-3) 230V 400V 500V 600V - 200 - - 2033-C0420P ...
Page 15
... IP 30 Enclosure 2030-PP0071 2030-PP0073 Safety Isolation System ElectroGuard 440V 50Hz 500V 50Hz 550V 50Hz Enclosure 2030-RLSWG Type 4 Watertight Type 4X Watertight Stainless Steel Enclosure 2030-PF1201 2030-PC1201 2030-PF1203 2030-PC1203 Catalogue Number IP 54 Enclosure IP 65 Enclosure 2030-PH0071 2030-PW0071 2030-PH0073 2030-PW0073 12-15 ...
Page 16
... To order the optional enclosed Expansion Module for field addition for North America: Description Type 1 Enclosure 4 port 2030-EUAF 4 port w/ time delay 2030-EUAF-1TDA 10 port 2030-EUAT 10 port w/time delay 2030-EUAT -1TDA To order the optional enclosed Expansion Module for field addition for outside of North America: ...
Page 17
Status Communication to a remote PLC (Should be ordered with Safety Isolation System) This option provides Remote I/O via “Flex” modules. Communication can be via: • The DeviceNet communication platform, or • The Remote I/O communication platform. Note: The status ...
Page 18
Safety Isolation System ElectroGuard Typical Wiring Diagram/Wire Length Considerations Typical Wiring Diagram Safety Isolation System GC with Optional Fusible Disconnecting Means 1IC 2IC Designates Remote field Lockout connection Station(s) points Wire Length Considerations ATTENTION: ...
Page 19
The total wire length for the 5 RLS to be wired to the Control Module will be: 100ft + 400ft + 200ft + 600ft + 1,000ft = 2,300ft Per the table entitled Total Wire Length for Remote Lockout Stations on ...
Page 20
Safety Isolation System Notes 12-20 ...