2031-C0023HX ALLEN-BRADLEY [Allen-Bradley], 2031-C0023HX Datasheet
2031-C0023HX
Related parts for 2031-C0023HX
2031-C0023HX Summary of contents
Page 1
Safety Isolation System ElectroGuard Overview The ElectroGuard Safety Isolation System is used in place of a disconnect switch for Lockout and Tagout (LOTO). It uses power contactors and Remote Lockout Stations to accomplish LOTO. Isolating the electrical energy usually involves ...
Page 2
Principle of Operation Power Circuit 1IC 2IC Incoming 3 Phase Power Trans Control Power Grd Disconnecting Means/Branch Circuit Protection Control Circuit Remote Lockout Station Off On VDR GC Available factory installed within the ElectroGuard as ...
Page 3
... Line Side Incoming Power Cables and 1200A Load Side Outgoing Bus Input Line Voltage Code The Catalogue Number as listed is incomplete. Select an Input Line Voltage Code from the table below. Example: Catalogue Number 2031-C0085P becomes Catalogue Number 2031-C0085PN for a 380V 50Hz Input Line Voltage application. Input Line Voltage 220V 50HZ ...
Page 4
... Step 1: Add the following Catalogue String to the Safety Isolation System Catalogue Number: To indicate that the Safety Isolation System should be supplied as “Pneumatic Ready.” e.g. 2031-A0085JB-1PN to indicate an 85A Safety Isolation System that “Pneumatic Ready.” Step 2: Order suitably enclosed Pneumatic Isolation Module as separate item: For North America: Pressure ...
Page 5
... Internal Provisions to Accommodate Isolation System Expansion Modules 23A - 85A Provisions to accept one (1) Expansion 110A - 420A Module (Bulletins 2031, 2032 or 2033) Provisions to accept up to two (2) Expansion Modules in Bulletin 2032 or 2033 630A - 1200A combination systems, or one (1) Expansion Module in Bulletin 2031 non combination systems. ...
Page 6
... To order metering, add one or more of the following Catalogue Strings to the Safety Isolation System Catalogue Number: Type of Metering Required Single-phase Ammeter Three-phase Ammeter Single-phase Voltmeter Three-phase Voltmeter e.g. Catalogue Number 2031-A0085JB becomes Catalogue Number 2031-A0085JB-1AM to indicate an 85A Safety Isolation System that includes a cover mounted single-phase Ammeter. Number of I/O points 16 points 32 points 48 points 64 points ...
Page 7
Safety Isolation System ElectroGuard Typical Wiring Diagram/Wire Length Considerations Typical Wiring Diagram Safety Isolation System GC with Optional Fusible Disconnecting Means 1IC 2IC Designates Remote field Lockout connection Station(s) points Wire Length Considerations ATTENTION: ...
Page 8
The total wire length for the 5 RLS to be wired to the Control Module will be: 100ft + 400ft + 200ft + 600ft + 1,000ft = 2,300ft Per the table entitled Total Wire Length for Remote Lockout Stations on ...