pva100p6rq Banner Engineering Corp., pva100p6rq Datasheet - Page 5

no-image

pva100p6rq

Manufacturer Part Number
pva100p6rq
Description
Pva Series Parts Verification Array Light Screen For Error Proofing Of Bin-picking Operations
Manufacturer
Banner Engineering Corp.
Datasheet
Figure 2. PVA installation: alternate
Emitter
Banner Engineering Corp.
Receiver
www.bannerengineering.com • Tel: 763.544.3164
Emitter
multiple pairs of emitters and
receivers to avoid crosstalk.
Receiver
Receiver
Emitter
Receiver
Minneapolis, MN U.S.A.
Emitter
Positioning
When multiple pairs of sensors are mounted in a confined area, care must be taken to
avoid crosstalk between the various sensor pairs. There are several ways to avoid
crosstalk:
• Alternate the relative position of the emitters and receivers as shown in Figure 2.
• Alternate the programming of adjacent pairs, from Frequency A to Frequency B (see
• The effective maximum range of the PVA sensors is approximately 2 m (6.5'), so
Figure 3. Improper orientation; emitter and receiver pairs should be mounted parallel, with
Figure 4. Maximum off-axis misalignment
Programming, page 7).
sensor pairs located farther than that from one another are unlikely to cause
crosstalk problems.
Vertical Misalignment
Cables ends pointing in
opposite directions
both cable ends pointing the same direction.
X
PVA Series Parts Verification Array
Horizontal Misalignment
X
Installation
Y
Y
Sensor Separation – Y
(Meters)
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
Maximum Off-axis Distance – X
50
(Millimeters)
100
150
Non-parallel
orientation
P/N 52088 rev. D