SAA7380GP Philips Semiconductors, SAA7380GP Datasheet - Page 18

no-image

SAA7380GP

Manufacturer Part Number
SAA7380GP
Description
Error correction and host interface IC for CD-ROM ELM
Manufacturer
Philips Semiconductors
Datasheet
Philips Semiconductors
7.7.14
Resetting the chip clears all bits in this register.
Table 9 STAT0 register bits
7.7.15
Resetting the chip clears all bits in this register.
The bits in this register indicate the reliability of data in the HEAD0 to HEAD3 registers. Bits MINERR, SECERR,
BLKERR and MODERR indicate errors in the minutes, seconds, frames and mode bytes in the header of the current
block. Bits SH0ERR to SH3ERR indicate errors in the respective bytes in the sub-header.
Table 10 STAT1 register bits
1996 Apr 25
Error correction and host interface IC for
CD-ROM (ELM)
MINERR
BIT 7
BIT
7
6
5
4
3
2
1
0
STAT0
STAT1
SECERR
NOSYNC
ERABLK
UCEBLK
CRCOK
ILSYNC
NAME
BIT 6
SBLK
LBLK
Cyclic redundancy check not OK = 0; Cyclic redundancy check OK = 1. Set by the
EDC in accordance with the results of the CRC check.
Sync pattern detected at word count 0 to 1174 or 1176 onwards = 1. This bit is set to
logic 1 if the sync pattern in the incoming data is detected between word counts
0 and 1174 or 1176 to infinity, and the decoder has been retimed. Due to the
presence of the cache RAM, it is necessary to stop error correction also when long
blocks have been detected.
Sync pattern inserted by sync interpolator not coincident with data sync = 1. This bit
is set to logic 1, if the word counter reaches 1175 and no sync pattern has been
detected in the input data. It indicates that the sync interpolator circuit inserted a
sync.
With SYIEN = 0, no sync found. Data block size has been extended = 1. This bit is
set to logic 1, if the sync interpolator was switched off, and if the sync interpolator
indicated that sync insertion was necessary. This condition causes the block length to
be extended.
Reserved
Short block indication = 1. This bit is set to logic 1 if the decoder is not retimed when
a sync pattern is detected in an incorrect word location, and is ignored while the
SYDEN bit is set to logic 0.
One or more bytes of the block are flagged with C2 flags = 1. This bit is set to logic 1
if one or more bytes of the current block contain erasures as indicated by the C2PO
input.
Uncorrectable errors in block = 1. This bit is set to logic 1 when one or more bytes of
the current block remain in error after the error correction process.
BLKERR
BIT 5
MODER
BIT 4
18
SH0ERR
BIT 3
FUNCTION
SH1ERR
BIT 2
SH2ERR
BIT 1
Preliminary specification
SAA7380
SH3ERR
BIT 0

Related parts for SAA7380GP