Setting CL_DISC to 1 (Table 21) enables port over
class current protection, where MAX5952 scales down
the overcurrent limit (V
classification status. This feature provides protection to
the system against PDs that violate their maximum
class current allowance.
The higher current setting is enabled only after a suc-
cessful startup so that the PD powers up as a normal
15W device.
Power-enable pushbutton for semi and manual modes
is found in Table 22. Setting PWR_ON_ to 1 turns on
power to the corresponding port. Setting PWR_OFF_ to
1 turns off power to the port. PWR_ON is ignored when
the port is already powered and during shutdown.
PWR_OFF is ignored when the port is already off and
Table 21. Miscellaneous Configurations 1
Table 22. Power-Enable Pushbuttons
INT_EN
RSTR_EN
Reserved
Reserved
POFF_CL
CL_DISC
OUT_ISO
PWR_OFF4
PWR_OFF3
PWR_OFF2
PWR_OFF1
PWR_ON4
PWR_ON3
PWR_ON2
PWR_ON1
SYMBOL
SYMBOL
ADDRESS = 17h
ADDRESS = 19h
______________________________________________________________________________________
BIT
BIT
7
6
5
4
3
2
1
7
6
5
4
3
2
1
0
FLT_LIM
R/W
R/W
R/W
R/W
R/W
W
W
W
W
W
W
W
W
R
R
R
R
) according to the port
High-Power, Quad, PSE Controller
A logic-high enables INT functionality
A logic-high enables the autorestart protection time off (as set by the RSRT[1:0] bits)
Reserved
Reserved
A logic-high prevents power-up after a classification failure (I > 50mA, valid only in AUTO
mode)
A logic-high enables reduced current-limit voltage threshold (V
Forces DET_ to high impedance. Does not interfere with other circuit operation.
A logic-high powers off port 4
A logic-high powers off port 3
A logic-high powers off port 2
A logic-high powers off port 1
A logic-high powers on port 4
A logic-high powers on port 3
A logic-high powers on port 2
A logic-high powers on port 1
for Power-Over-Ethernet
CL_DISC, together with EN_HP_CL_ (R15h [6:4]),
EN_HP_ALL (R15h [7]), and ENx_CL6 (R1Ch [7:4]) are
used to program the high-power mode. See Table 3 for
details.
Setting OUT_ISO high (Table 21), forces DET_ to a
high-impedance state.
A reset sets R17h = 0xC0.
during shutdown. After execution, the bits reset to 0.
During detection or classification, if PWR_ON_ goes
high, the MAX5952 gracefully terminates the current
operation and turns on power to the port. The MAX5952
ignores the PWR_ON_ in auto mode. A reset sets R19h
= 00h.
DESCRIPTION
DESCRIPTION
FLT_LIM