W25X32 WINBOND [Winbond], W25X32 Datasheet - Page 21

no-image

W25X32

Manufacturer Part Number
W25X32
Description
16M-BIT, 32M-BIT, AND 64M-BIT SERIAL FLASH MEMORY WITH 4KB SECTORS AND DUAL OUTPUT SPI
Manufacturer
WINBOND [Winbond]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W25X32AFIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X32AVSFIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X32V
Manufacturer:
WIN
Quantity:
1 000
Part Number:
W25X32VFIG
Manufacturer:
VLSI
Quantity:
1 831
Part Number:
W25X32VFIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X32VSFIG
Manufacturer:
Winbond
Quantity:
536
Part Number:
W25X32VSFIG
Manufacturer:
ST
0
Part Number:
W25X32VSFIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Part Number:
W25X32VSIG
Manufacturer:
WINBOND/华邦
Quantity:
20 000
Company:
Part Number:
W25X32VSIG
Quantity:
178
Part Number:
W25X32VSSIG
Manufacturer:
WINBOND
Quantity:
23 988
Part Number:
W25X32VSSIG
Manufacturer:
ST
0
Part Number:
W25X32VSSIGE
Manufacturer:
MAXIM
Quantity:
236
W25X16, W25X32, W25X64
11.2.7 Read Data (03h)
The Read Data instruction allows one more data bytes to be sequentially read from the memory. The
instruction is initiated by driving the /CS pin low and then shifting the instruction code “03h” followed
by a 24-bit address (A23-A0) into the DIO pin. The code and address bits are latched on the rising
edge of the CLK pin. After the address is received, the data byte of the addressed memory location
will be shifted out on the DO pin at the falling edge of CLK with most significant bit (MSB) first. The
address is automatically incremented to the next higher address after each byte of data is shifted out
allowing for a continuous stream of data. This means that the entire memory can be accessed with a
single instruction as long as the clock continues. The instruction is completed by driving /CS high. The
Read Data instruction sequence is shown in figure 8. If a Read Data instruction is issued while an
Erase, Program or Write cycle is in process (BUSY=1) the instruction is ignored and will not have any
effects on the current cycle. The Read Data instruction allows clock rates from D.C. to a maximum of
f
(see AC Electrical Characteristics).
R
Figure 8. Read Data Instruction Sequence Diagram