BD6086GU_11 ROHM [Rohm], BD6086GU_11 Datasheet - Page 12

no-image

BD6086GU_11

Manufacturer Part Number
BD6086GU_11
Description
13LEDs ALC* Flash and Illumination
Manufacturer
ROHM [Rohm]
Datasheet
● Timing diagram
● Electrical Characteristics(Unless otherwise specified, Ta=25 ℃ , VBAT=3.6V, VIO=1.8V)
© 2011 ROHM Co., Ltd. All rights reserved.
www.rohm.com
BD6086GU
【 I
SCL clock frequency
LOW period of the SCL clock
HIGH period of the SCL clock
Hold time (repeated) START condition
After this period, the first clock is generated
Set-up time for a repeated START condition
Data hold time
Data set-up time
Set-up time for STOP condition
Bus free time between a STOP
and START condition
2
SCL
SDA
C BUS format 】
S
Parameter
t
HD;STA
t
LOW
t
HD;DAT
t
SU;DAT
t
HIGH
Symbol
t
t
t
t
t
SU;STO
HD;STA
SU;STA
HD;DAT
SU;DAT
t
t
f
t
HIGH
LOW
BUF
SCL
12/80
Sr
Min.
250
4.7
4.0
4.0
4.7
4.0
4.7
0
0
t
t
SU;STA
HD;STA
Standard-mode
Typ.
-
-
-
-
-
-
-
-
-
Max.
3.45
100
-
-
-
-
-
-
-
t
SU;STO
Min.
100
1.3
0.6
0.6
0.6
0.6
1.3
0
0
P
Fast-mode
t
BUF
Typ.
-
-
-
-
-
-
-
-
-
S
Technical Note
2011.04 - Rev.A
Max.
400
0.9
-
-
-
-
-
-
-
Unit
kHz
μs
μs
μs
μs
μs
ns
μs
μs

Related parts for BD6086GU_11