UPG158 NEC, UPG158 Datasheet
UPG158
Available stocks
Related parts for UPG158
UPG158 Summary of contents
Page 1
... Marking PG158TB-E3 G1M Remark To order evaluation samples, please contact your local NEC sales office. (Part number for sample order: PG158TB) Caution The IC must be handled with care to prevent static discharge because its circuit is composed of GaAs MES FET. The information in this document is subject to change without notice. Before using this document, please confirm that this is the latest version ...
Page 2
... Input Power Total Power Dissipation Operating Temperature Storage Temperature Note Condition 2 CONT1 CONT2 Remarks 1. Mounted Operation in excess of any one of these parameters may result in permanent damage. PIN CONNECTIONS Pin No. Connection Pin No. 1 OUT1 4 2 GND 5 3 OUT2 6 RECOMMENDED OPERATING CONDITIONS (T ...
Page 3
... All other characteristics are measured in linear range. Cautions 1. When the PG158TB is used it is necessary to use DC blocking capacitors for No. 1 (OUT1), No.3 (OUT2) and No.5 (IN). The value of DC blocking capacitors should be chosen to accommodate the frequency of operation, band width, switching speed and the condition with actual board of your system ...
Page 4
TYPICAL CHARACTERISTICS TEST CONDITIONS V CONT OUT1 IN OUT2 50 IN-OUT1 INPUT RETURN LOSS vs. FREQUENCY CH1 S log MAG 10 dB/ REF MARKER 1 1 GHz 0 –10 1 –20 –30 ...
Page 5
... TEST CIRCUIT CONT1 CONT2 Off chip DC blocking capacitors value pF 1000 pF (Bypass), Using NEC standard evaluation board EVALUATION BOARD = GHz CONT1 CONT2 OUT1 OUT2 CONT1 ...
Page 6
TRUTH TABLE OF SWITCHING BY CONDITION OF CONTROL VOLTAGE V V CONT2 CONT( CONT(L) IN PACKAGE DIMENSIONS 6 PIN SUPER MINIMOLD (UNIT: mm) +0.1 0.2 – CONT1 V CONT(H) OUT1 IN OUT2 OUT1 IN OUT2 0.7 ...
Page 7
... RECOMMENDED SOLDERING CONDITIONS This product should be soldered under the following recommended conditions. conditions other than those recommended below, contact your NEC sales representative. Soldering Method Infrared Reflow Package peak temperature: 235 °C or below Time: 30 seconds or less (at 210 °C) Count: 3, Exposure limit: None VPS Package peak temperature: 215 ° ...
Page 8
... Specific: Aircraft, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance ...