SLIN-02E2A BEL [Bel Fuse Inc.], SLIN-02E2A Datasheet - Page 20

no-image

SLIN-02E2A

Manufacturer Part Number
SLIN-02E2A
Description
NON-ISOLATED DC/DC CONVERTERS
Manufacturer
BEL [Bel Fuse Inc.]
Datasheet
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel.
The thermal reference point, T
temperature at this point should not exceed 140
power of the module (Vo,set x Io,max).
January 14, 2011
NON-ISOLATED DC/DC CONVERTERS
3 Vdc - 14 Vdc Input, 0.6 Vdc - 5.5 Vdc /2 A Outputs
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 •
Preferred airflow direction and location of hot-spot of the module (T
ref
Wind Tunnel
, used in the specifications is also shown below. For reliable operation the
PWBs
Thermal Test Setup
o
C. The output power of the module should not exceed the rated
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
ref
).
www.belfuse.com
20