MSP3411G Micronas, MSP3411G Datasheet - Page 27

no-image

MSP3411G

Manufacturer Part Number
MSP3411G
Description
(MSP34x1G) Multistandard Sound Processor Family
Manufacturer
Micronas
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MSP3411G
Manufacturer:
MICRONAS
Quantity:
5 510
Part Number:
MSP3411G
Manufacturer:
NSC
Quantity:
5 510
Part Number:
MSP3411G
Manufacturer:
MICRONAS
Quantity:
1 000
Part Number:
MSP3411G
Manufacturer:
MICRONAS
Quantity:
20 000
Company:
Part Number:
MSP3411G B8 V3
Quantity:
27
Part Number:
MSP3411G-B8-V3
Manufacturer:
MICRONAS
Quantity:
580
Company:
Part Number:
MSP3411G-B8-V3
Quantity:
2 000
Part Number:
MSP3411G-FH-B8-V3
Manufacturer:
Micronas
Quantity:
650
Part Number:
MSP3411G-PO-B8-V3
Manufacturer:
AMIC
Quantity:
1 350
Company:
Part Number:
MSP3411G-QA-B8-V3-G
Quantity:
2 000
Part Number:
MSP3411G-QA-B8V3
Manufacturer:
MICRONS
Quantity:
20 000
Part Number:
MSP3411G-QA-C12
Manufacturer:
MICRONAS
Quantity:
1 000
Part Number:
MSP3411G-QA-C12
Manufacturer:
MICRONAS
Quantity:
20 000
Part Number:
MSP3411GA2
Manufacturer:
MICRONAS
Quantity:
20 000
PRELIMINARY DATA SHEET
3.3.2.3. STANDARD RESULT Register
If Automatic Standard Detection is selected in the
STANDARD SELECT register, status and result of the
Automatic Standard Detection process can be read out
of the STANDARD RESULT register. The possible
results are based on the mentioned Standard Code
and are listed in Table 3–8.
In cases where no sound standard has been detected
(no standard present, too much noise, strong interfer-
ers, etc.) the STANDARD RESULT register contains
00 00
actions (for example, set the standard according to a
preference list or by manual input).
As long as the STANDARD RESULT register contains
a value greater than 07 FF
Detection is still active. During this period, the MODUS
and STANDARD SELECT register must not be written.
The STATUS register will be updated when the Auto-
matic Standard Detection has finished.
If a present sound standard is impossible for a specific
MSP version, it detects and switches to the analog
mono sound of this standard.
Example:
The MSPs 3431G and 3441G will detect a B/G-NICAM
signal as standard 3 and will switch to the analog FM-
Mono sound.
MICRONAS INTERMETALL
hex
. In that case, the controller has to start further
hex
, the Automatic Standard
Table 3–8: Results of the Automatic Standard
Detection
Broadcasted Sound
Standard
Automatic Standard
Detection could not
find a sound standard
B/G-FM
B/G-NICAM
I
FM-Radio
M-Korea
M-Japan
M-BTSC
L-AM
D/K1
D/K2
L-NICAM
D/K-NICAM
Automatic Standard
Detection still active
STANDARD RESULT Register
Read 007E
>07FF
0000
0003
0008
000A
0040
0002
0020
0030
0009
0004
0009
000B
hex
hex
hex
hex
hex
hex
hex
hex
hex
hex
hex
hex
hex
MSP 34x1G
(if MODUS[14,13]=00)
(if MODUS[14,13]=01)
(if MODUS[14,13]=10)
(if MODUS[12]=0)
(if MODUS[12]=1)
(if MODUS[12]=0)
(if MODUS[12]=1)
hex
27