allow water flow to the humidifier. Set the Humidistat or
INTELLISTAT™ control to highest demand (99% humidity).
When the humidifier is on (mist spray is activated), the red
LED on the humidifier will be on.
control, the red LED will go on and off with the MICRO-
PULSE™ control sequence.
fier and remove from unit. Attach a 2-ft. section of tube to bot-
tom of humidifier and top of filter. Hold humidifier outside of
the plenum and check to see that the spray mist is functioning
correctly. Reinstall humidifier and replace original tubing.
the humidifier is operating correctly. (See Troubleshooting
section.)
levels (below 20% relative humidity [RH]), it may take 4 to 6
weeks to notice an increase in humidity in the home. In low
humidity areas all the moisture has evaporated from the wood,
drywall, carpets, draperies, and furniture. Until this moisture is
replaced, these materials will absorb moisture from the air,
causing very little relative humidity rise in the home.
only increase the moisture in the house when the fan is
running. Therefore, in climates where little heating is required
and the heating/fan system is therefore run very few hours per
RH —
Table 1 — Recommended Indoor Humidity Levels
To start up the humidifier, open all supply water valves to
When connected to an INTELLIMIST™ or Humidistat
Spray mist operational check: Remove screws from humidi-
Reset the Humidistat to the recommended setting once
For homes that are in very dry climates with low humidity
As with any whole-house humidifier, the humidifier can
OUTSIDE TEMP (F)
LEGEND
Relative Humidity
–10
–20
40
30
20
10
0
OPERATION
RECOMMENDED RH
45%
40%
35%
30%
25%
20%
15%
5
day, the fan must be run in the non-heating modes to increase
the humidity in the rooms. (See Tables 1 and 2.)
This can be accomplished in one of three ways.
to 24 gallons of water into the air per day, it may not be possi-
ble to increase the humidity to a high level, especially if the
outside humidity is fairly low. For instance, when outdoor air at
40 F and 20% relative humidity is heated up to 72 F, the result-
ing humidity in the house is 8%. The amount of humidity that
can be added to the air is limited by the airflow in the ductwork
and the temperature of the air. Hot air (furnace is running) can
hold 6 times as much moisture as the air can hold when only
the fan is running. It is much easier to increase the humidity in
the house with the furnace running versus when only the fan is
running. Both applications are limited by the amount of mois-
ture that can be put into the air going through the ductwork
without the moisture actually condensing in the ductwork.
NOTE: With a constant indoor temperature of 70 F.
RH —
1. The INTELLISTAT control can be set to ON (see
2. The fan (see INTELLISTAT control Installation
3. The fan can be run continuously with the fan ON
INDOOR RH
Even though the INTELLIMIST humidifier can put out up
(% RH)
INTELLISTAT control Installation Instructions), then
the INTELLISTAT will run the fan and humidifier any
time the humidity is below the set point.
Instructions) can be programmed to run so many min-
utes per hour during certain hours of the day. The
humidifier will run any time the fan runs and the
humidity is below the set point.
button. The humidifier will then run constantly on a
call for humidity.
Table 2 — Outside Temperature at Which
50
45
40
35
30
25
20
15
10
LEGEND
Relative Humidity
Condensation is Likely to Occur
Single Pane
WINDOW TYPE/CONDENSING TEMP (°F)
–11
43
38
34
28
22
15
8
0
Double Pane
–20
–30
18
11
–8
2
Triple Pane
–10
–25
–35
10
0