EN29GL064 EON [Eon Silicon Solution Inc.], EN29GL064 Datasheet

no-image

EN29GL064

Manufacturer Part Number
EN29GL064
Description
64 Megabit (8192K x 8-bit / 4096K x 16-bit) Flash Memory Page mode Flash Memory, CMOS 3.0 Volt-only
Manufacturer
EON [Eon Silicon Solution Inc.]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
EN29GL064H-70ZIP
Quantity:
133
Company:
Part Number:
EN29GL064L-70ZIP
Quantity:
217
FEATURES
The EN29GL064 offers a fast page access time of 25 ns with a corresponding random access time as
fast as 70 ns. It features a Write Buffer that allows a maximum of 16 words/32 bytes to be programmed
in one operation, resulting in faster effective programming time than standard programming algorithms.
This makes the device ideal for today’s embedded applications that require higher density, better
performance and lower power consumption.
This Data Sheet may be revised by subsequent versions
or modifications due to changes in technical specifications.
EN29GL064
64 Megabit (8192K x 8-bit / 4096K x 16-bit) Flash Memory
Page mode Flash Memory, CMOS 3.0 Volt-only
• Single power supply operation
- Full voltage range: 2.7 to 3.6 volts read and
• High performance
- Access times as fast as 70 ns
• V
- All input levels (address, control, and DQ input
• 8-word/16-byte page read buffer
• 16-word/32-byte write buffer reduces overall
• Secured Silicon Sector region
- 128-word/256-byte sector for permanent,
- Can be programmed and locked at the factory
- Boot sector models:
• Flexible Sector Architecture:
- Uniform sector models:
levels) and outputs are determined by voltage
on V
secure identification through an 8-word/16-
byte random Electronic Serial Number
or by the customer
One hundred and twenty-eight uniform
32Kword/64Kbyte sectors
programming time for multiple-word updates
write operations
and one hundred twenty-seven 32Kword /
64Kbyte sectors.
Eight 8-Kbyte boot sectors on Top or Bottom
GENERAL DESCRIPTION
IO
Input/Output 1.65 to 3.6 volts
IO
input. V
IO
range is 1.65 to V
CC
Rev. M, Issue Date: 2011/04/13
1
• Suspend and Resume commands for
• Write operation status bits indicate program
• Support for CFI (Common Flash Interface)
• Persistent methods of Advanced Sector
• WP#/ACC input
- Accelerates programming time (when V
- Protects first or last sector regardless of
• Hardware reset input (RESET#) resets
• Ready/Busy# output (RY/BY#) detects
• Minimum 100K program/erase endurance
• Package Options
- 56-pin TSOP
- 64-ball 11mm x 13mm BGA
• Industrial Temperature Range.
applied) for greater throughput during system
production
sector protection settings
cycles.
Program and Erase operations
and erase operation completion
Protection
device
program or erase cycle completion
©2004 Eon Silicon Solution, Inc.,
EN29GL064
www.eonssi.com
HH
is

Related parts for EN29GL064

EN29GL064 Summary of contents

Page 1

... GENERAL DESCRIPTION The EN29GL064 offers a fast page access time with a corresponding random access time as fast as 70 ns. It features a Write Buffer that allows a maximum of 16 words/32 bytes to be programmed in one operation, resulting in faster effective programming time than standard programming algorithms. ...

Page 2

... RFU 28 RFU Note: RFU= Reserved for future use This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 2 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 RFU 56 RFU 55 A16 54 BYTE# 53 Vss 52 DQ15/A-1 51 DQ7 50 DQ14 ...

Page 3

... D5 E5 A19 DQ5 D4 E4 A20 DQ2 DQ0 RFU RFU 3 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 RFU RFU RFU BYTE# DQ15 / A -1 VSS DQ14 DQ13 DQ6 DQ12 VCC DQ4 ...

Page 4

... Not Connected to anything This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. FIGURE 3. LOGIC DIAGRAM A0 – A21 CE# OE# WE# Reset# WP#/ACC Byte ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 EN29GL064 DQ0 – DQ15 (A-1) RY/BY# www.eonssi.com ...

Page 5

... V =1.65 – 3 Blo ck Protect Switches Erase Voltage Gen erator Program Voltage Generator STB Timer 5 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 EN29GL064 - DQ0-DQ15 (A-1) Inp ut/Output Buffers STB Chip Enable Data Latch Output Enable Logic Y-Decoder ...

Page 6

... Product Overview EN29GL064 is 64 Mb, 3.0-volt-only, page mode Flash devices optimized for today’s embedded designs that demand a large storage array and rich functionality. Additional features include: • Single word programming or a 16-word buffer for an increased programming speed • Program Suspend/Resume and Erase Suspend/Resume • ...

Page 7

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 Address Range Word mode (x16) 000000h–007FFFh 008000h–00FFFFh 010000h–017FFFh 018000h–01FFFFh 020000h–027FFFh 028000h–02FFFFh 030000h–037FFFh 038000h–03FFFFh 040000h–047FFFh 048000h– ...

Page 8

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 140000h–147FFFh 148000h–14FFFFh 150000h–157FFFh 158000h–15FFFFh 160000h–167FFFh 168000h–16FFFFh 170000h–177FFFh 178000h–17FFFFh 180000h–187FFFh 188000h–18FFFFh 190000h–197FFFh 198000h–19FFFFh 1A0000h– ...

Page 9

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 298000h–29FFFFh 2A0000h–2A7FFFh 2A8000h–2AFFFFh 2B0000h–2B7FFFh 2B8000h–2BFFFFh 2C0000h–2C7FFFh 2C8000h–2CFFFFh 2D0000h–2D7FFFh 2D8000h–2DFFFFh 2E0000h–2E7FFFh 2E8000h–2EFFFFh 2F0000h–2F7FFFh 2F8000h– ...

Page 10

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 3F0000h–3F7FFFh 3F8000h–3FFFFFh Address Range (h) Word Mode (x16) 000000–007FFF 008000–00FFFF 010000–017FFF 018000–01FFFF 020000–027FFF 028000–02FFFF 030000–037FFF 038000– ...

Page 11

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 128000–12FFFF 130000–137FFF 138000–13FFFF 140000–147FFF 148000–14FFFF 150000–157FFF 158000–15FFFF 160000–167FFF 168000–16FFFF 170000–177FFF 178000–17FFFF 180000– ...

Page 12

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 280000–287FFF 288000–28FFFF 290000–297FFF 298000–29FFFF 2A0000–2A7FFF 2A8000–2AFFFF 2B0000–2B7FFF 2B8000–2BFFFF 2C0000–2C7FFF 2C8000–2CFFFF 2D0000–2D7FFF 2D8000– ...

Page 13

... SA130 1111111011 PPB 38 SA131 1111111100 PPB 39 SA132 1111111101 PPB 40 SA133 1111111110 PPB 41 SA134 1111111111 Table 3C. Bottom Boot Sector / Persistent Protection Sector Group Address Tables (EN29GL064B) PPB Sector A21 – A12 Group PPB 0 SA0 0000000000 PPB 1 SA1 0000000001 PPB 2 SA2 0000000010 PPB 3 ...

Page 14

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 0A0000–0A7FFF 0A8000–0AFFFF 0B0000–0B7FFF 0B8000–0BFFFF 0C0000–0C7FFF 0C8000–0CFFFF 0D0000–0D7FFF 0D8000–0DFFFF 0E0000–0E7FFF 0E8000–0EFFFF 0F0000–0F7FFF 0F8000– ...

Page 15

... Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 1F8000–1FFFFF 200000–207FFF 208000–20FFFF 210000–217FFF 218000–21FFFF 220000–227FFF 228000–22FFFF 230000–237FFF 238000–23FFFF 240000–247FFF 248000–24FFFF 250000– ...

Page 16

... 0. L L/H 16 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 350000–357FFF 358000–35FFFF 360000–367FFF 368000–36FFFF 370000–377FFF 378000–37FFFF 380000–387FFF 388000–38FFFF 390000–397FFF 398000–39FFFF 3A0000–3A7FFF 3A8000–3AFFFF 3B0000–3B7FFF 3B8000–3BFFFF 3C0000– ...

Page 17

... The device only support to use autoselect command to access autoselect codes. It does not support to apply VID on address pin A9. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. range is 1. ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 . For example www.eonssi.com ...

Page 18

... Programming to the same address multiple times continuously (for example, “walking” a bit within a word) is permitted. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 18 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 19

... Figure 4. Single Word Program This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 19 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 20

... DQ6 = TOGGLE, DQ5 = 0. This indicates that the Write Buffer Programming Operation was ABORTED. Note that the Secured Silicon sector, autoselect, and CFI functions are unavailable when a program This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 20 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 21

... Use of the write buffer is strongly recommended for programming when multiple words are to be programmed. Figure 5. Write Buffer Programming Operation This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 21 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 22

... This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. START Write Erase Command Sequence Data Poll from System or Toggle Bit successfully completed Data =FFh? No Yes Erase Done 22 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 23

... Erase Suspend or Program Suspend read is needed from the Secured Silicon Sector area, then user must use the proper command sequences to enter and exit this region. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 23 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 24

... This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications for operations other than accelerated programming, or device HH after power-up sequence is completed. In addition VIH/VIL before powering down ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 from the ACC www.eonssi.com ...

Page 25

... WE# pulse in the command sequence (prior to the program or erase operation), and during the sector erase time-out. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 25 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 26

... DQ7 status bit as the alternative method of determining the active or inactive status of the write operation. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 26 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 27

... DQ7# Toggle 0 N/A 0 Toggle 0 Invalid (Not allowed) Data N/A Toggle Data DQ7# Toggle 0 N/A DQ7# Toggle 0 N/A DQ7# Toggle 0 N/A 27 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 DQ2 DQ1 RY/BY# (note Toggle 1 Toggle N Toggle N N/A N www.eonssi.com ...

Page 28

... This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. . This feature allows the host system to detect when data is CC reset current (ICC5). If RESET# is held at VIL, but CC 28 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 29

... This section describes the various methods of protecting data stored in the memory array. An overview of these methods in shown in Figure 8. Figure 8a. Advanced Sector Protection/Unprotection for Uniform Sector This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 29 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 30

... Figure 8b. Advanced Sector Protection/Unprotection for Top Boot Sector This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 30 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 31

... DQ4. If DQ0 is ‘0’, it means that the Customer Secured Silicon area is locked and if DQ0 is ‘1’, it means that it is unlocked. When DQ1 is set to ‘0’, the device is used in the Persistent Protection Mode. DQ3 is This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 31 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 32

... Reserved Programmable Bit 0 = All PPB Erase Command disabled 1 = All PPB Erase (default = 1) Command enabled (default = 1) 32 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 DQ1 DQ0 Persistent Secured Protection Mode Silicon Sector Lock Bit Protection Bit 0 = Persistent 0 = protected Protection enabled ...

Page 33

... Figure 9. PPB Program Algorithm Note base address This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 33 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 34

... The PPB Lock Bit must be set (programmed to “0”) only after all PPBs are configured to the desired settings. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 34 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 35

... Figure 10. Lock Register Program Algorithm Advanced Sector Protection Software Examples Table 7. Sector Protection Schemes: DYB, PPB and PPB Lock Bit Combinations This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 35 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 36

... If WE# = CE# = RESET# = VIL and OE# = VIH during power up, the device does not accept commands on the rising edge of WE#. The internal state machine is automatically reset to the read mode on power-up. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 36 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 37

... The ACC function is not available when the Secured Silicon Sector is enabled. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ± 0.3 V. The device requires standard access time (tCE) for read CC 37 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 38

... This mode of operation continues until the system issues the Exit Secured Silicon Sector command sequence, or until power is removed from the device. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 38 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 39

... This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Description Description N µs N µs (00h = not supported (00h = not supported) N times typical N times typical N times typical N times typical (00h = not supported) 39 ©2004 Eon Silicon Solution, Inc., Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 40

... CFI specification of CFI publication 100) 33h 0000h EN29GL064 H and L : 0000h, 0000h, 0000h, 0000h 34h 000xh EN29GL064 B and T : 007Eh, 0000h, 0000h, 0001h 35h 0000h 36h 0000h Erase Block Region 3 Information 37h 0000h (refer to the CFI specification of CFI publication 100) ...

Page 41

... Program Suspend Latency Maximum 2 Bank Organization 57h 0000h 00 = Data at 4Ah is zero Number of Banks This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications µs N µs ©2004 Eon Silicon Solution, Inc., 41 Rev. M, Issue Date: 2011/04/13 EN29GL064 N bytes www.eonssi.com ...

Page 42

... Table 13. EN29GL064 Command Definitions Command Sequence Read 1 Reset 1 Word Manufacturer 4 ID Byte Device ID Word 4 Uniform Byte Device ID Word 4 Top Boot Byte Word Device ID 4 Bottom Boot Byte Word Sector Protect 4 Verify Byte Word Program 4 Byte Word Write to Buffer 6 Byte Word Program Buffer to ...

Page 43

... Table 14. EN29GL064 Command Definitions Command Sequence Word 3 Command Set Entry Byte 3 Program 2 Read 1 Command Set Exit 2 Word 3 PPB Command Set Entry Byte 3 PPB Program 2 All PPB Erase 2 PPB Status Read 1 PPB Command Set Exit 2 PPB Lock Word 3 Command Set Byte 3 Entry ...

Page 44

... WP#/ACC CE OE IL, IH, pin CCmax, WP#/ACC = V V pin 100μ -100μA OH ©2004 Eon Silicon Solution, Inc., 44 Rev. M, Issue Date: 2011/04/13 EN29GL064 Min Typ Max Unit ±5 µA ±1 µ 0 ...

Page 45

... Input timing measurement reference levels Output timing measurement reference levels This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. -70 Unit ©2004 Eon Silicon Solution, Inc., 45 Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 46

... OE OE Read Toggle and Polling DATA Addresses Stable t ACC Output Valid ©2004 Eon Silicon Solution, Inc., 46 Rev. M, Issue Date: 2011/04/13 EN29GL064 Speed Unit -70 Min 70 ns Max 70 ns Max 70 ns Max 25 ns Max 25 ns Max 20 ns ...

Page 47

... Figure 13. Page Read Operation Timings Note: Addresses are A2:A-1 for byte mode. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ©2004 Eon Silicon Solution, Inc., 47 Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 48

... Reset# Pin Low (NOT During Embedded Algorithms) t READY2 to Read or Write This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Description ©2004 Eon Silicon Solution, Inc., 48 Rev. M, Issue Date: 2011/04/13 EN29GL064 Speed Test Unit Setup -70 Min 10 us Min 500 ...

Page 49

... Reset Timing NOT during Embedded Algorithms This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. t READY1 t RP1 Reset Timing during Embedded Algorithms RP2 t READY2 ©2004 Eon Silicon Solution, Inc., 49 Rev. M, Issue Date: 2011/04/13 EN29GL064 t RB1 t RB2 www.eonssi.com ...

Page 50

... This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Test Setup Min Min Min t CBH Byte# timings for Read Operations t BCS Byte #timings for Write Operations ©2004 Eon Silicon Solution, Inc., 50 Rev. M, Issue Date: 2011/04/13 EN29GL064 Speed Unit - RBH www.eonssi.com ...

Page 51

... Toggle and Min Polling DATA# Min Min Min Min Min Typ Typ Max Typ Max Typ Min Min Max Min ©2004 Eon Silicon Solution, Inc., 51 Rev. M, Issue Date: 2011/04/13 EN29GL064 Speed Unit - ...

Page 52

... Description Min Min Min Min Min Min Min Min Min Min Typ Typ Max Typ Max ©2004 Eon Silicon Solution, Inc., 52 Rev. M, Issue Date: 2011/04/13 EN29GL064 Speed Unit - ...

Page 53

... 0x555 for chip erase WPH 0x30 10 for chip erase BUSY ©2004 Eon Silicon Solution, Inc., 53 Rev. M, Issue Date: 2011/04/13 EN29GL064 Read Status Data (last two cycles WHWH2 Status D OUT t RB =true data at read address. out www.eonssi.com ...

Page 54

... WPH t WHWH1 BUSY is the true data at the program address. OUT measurement references. It cannot occur as shown during a valid command VCS ©2004 Eon Silicon Solution, Inc., 54 Rev. M, Issue Date: 2011/04/13 EN29GL064 Program Command Sequence (last 2 cycles Status OUT t RB www.eonssi.com ...

Page 55

... Complement -ment Status Status Data Data Valid Status Valid Status (first read) (second read) ©2004 Eon Silicon Solution, Inc., 55 Rev. M, Issue Date: 2011/04/13 EN29GL064 VA True Valid Data True Valid Data VA VA Valid Data Valid Status (stops toggling) www.eonssi.com ...

Page 56

... PD for Program 0x30 for Sector Erase 0x10 for Chip Erase Enter Erase Erase Suspend Suspend Program Erase Enter Suspend Read ©2004 Eon Silicon Solution, Inc., 56 Rev. M, Issue Date: 2011/04/13 EN29GL064 VA WHWH2 Status D OUT Erase Resume Enter Erase Erase Suspend Suspend Program Read www ...

Page 57

... Test Setup OUT Test Conditions 150°C 125°C ©2004 Eon Silicon Solution, Inc., 57 Rev. M, Issue Date: 2011/04/13 EN29GL064 Comments Excludes 00h programming prior to erasure Excludes system level overhead Minimum 100K cycles Typ Max Unit 6 7 7.5 9 ...

Page 58

... B + 1.5 V for periods up to 20ns. See figure below - Full Voltage Range: 2.7 to 3.6V Vcc +1.5V ©2004 Eon Silicon Solution, Inc., 58 Rev. M, Issue Date: 2011/04/13 EN29GL064 Value Unit °C °C °C 200 –1.0V for periods Value Unit ° ...

Page 59

... FIGURE 22. 56L TSOP 14mm x 20mm package outline DIMENSION IN MM SYMBOL MIN 0. 20. 18. 14. 0.17 L 0.5 R 0.08 0 θ 0 Note : 1. Coplanarity: 0.1 mm This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. NOR MAX - - - 1. 0.15 1. 0.22 0.27 0.60 0.70 0.15 0. ©2004 Eon Silicon Solution, Inc., 59 Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 60

... FIGURE 23. 64-ball Ball Grid Array (BGA), 11 X13 mm, Pitch 1mm package outline DIMENSION IN MM SYMBOL MIN 0.40 A2 0.60 D 12.90 E 10. 0.50 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. NOR MAX - - - 1.40 0.50 0.60 0.66 0.76 13.00 13.10 11.00 11. 0.60 0.70 ©2004 Eon Silicon Solution, Inc., 60 Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 61

... Please contact your local sales office for additional information about Eon memory solutions. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. cFeon Top Marking Example: cFeon Part Number: XXXX-XXX Lot Number: XXXXX Date Code: XXXXX ©2004 Eon Silicon Solution, Inc., 61 Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 62

... ORDERING INFORMATION EN29GL064 The valid combinations of EN29GL064. Sector for Write Protect Base Part Number (WP#/ACC=L) EN29GL064 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications PACKAGING CONTENT P = RoHS compliant TEMPERATURE RANGE I = Industrial (-40°C to +85°C) PACKAGE Z = 56-pin TSOP BA = 64-Ball Ball Grid Array (BGA) 1 ...

Page 63

... A[max:12] should not be changes between Data=25h, Data=WC cycles to last Data= PD cycles and Data=29h cycle. Address 5ns CE# WE# Data This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. ERRATA SHEET Address Stable ©2004 Eon Silicon Solution, Inc., 63 Rev. M, Issue Date: 2011/04/13 EN29GL064 www.eonssi.com ...

Page 64

... Sector mode,..." on page 38. Add Write Buffer byte mode command and note that maximum value for word and byte mode in page 43 Correct the typo for The valid combinations of EN29GL064 table on H page 64. 1. Remove 48-pin TSOP package type information on page and 64 ...