EDS6-123I FUJI [Fuji Electric], EDS6-123I Datasheet - Page 2

no-image

EDS6-123I

Manufacturer Part Number
EDS6-123I
Description
ULTRASONIC FLOWMETER < M-Flow PW>
Manufacturer
FUJI [Fuji Electric]
Datasheet
2
FLR, FLS, FLY
Applicable flow pipe:
Velocity:
Power supply: 100 to 120V AC ±10%, 50/60Hz or 200 to
Signal cable: Co-axial cable up to 30m and thermal stabil-
Environment: Non-explosive environment without direct
Ambient temperature:
Ambient humidity:
Grounding:
Synchronization (option):
Arrester (option):
Note 1: Select FLSE31 or FLSE41 if the pipe is made of PP or PVDF.
Note 2: Select FLSE31 or FLSE41 for the pipes that do not transmit
Note 3: When the 9th digit in the code symbol is “A”, the applicable
Detector
FLSE12
FLSE22
FLSE31
FLSE41
The wall thickness of PP pipe is 15 mm or less, and that of
PVDF pipe is 9 mm or less.
ultrasound easily such as those made of cast iron, lining
pipes, and old steel pipes.
piping diameter is 50 to 150mm.
Internal pipe
ø25 to
ø50 to
ø50 to
Note 3
ø50 to
ø300 to
ø100mm
ø100mm
ø225mm
ø300mm
ø600mm
diameter
Liner: Tar epoxy, mortar, rubber, and others
Fundamental straight pipe:
0 to ±0.3 ... ±10m/s
240V AC ±10%, 50/60Hz or 20 to 30V DC
ity of 100 deg.C
sunlight, corrosive gas and heat radiation
-20 to +50deg.C for flow transmitter
-20 to +60deg.C for detector
90%RH or less
Class D (100 Ω or less)
Simultaneous transmission eliminates cross
talk between multiple flow meters and mu-
tual acoustic interference.
Number of connectable units: up to 31
Cable length: up to 15m
Master/Slave selectable
Arrester unit for outputs available (while ar-
rester for power supply incorporated as stan-
dard)
Plastic (PVC, etc.)
Note 1
Metal (stainless
steel, steel, copper,
aluminum, etc.)
Plastic (PVC, etc.)
Note 1
Metal (stainless
steel, steel, copper,
aluminum, etc.)
Note 2
Plastic
(PVC, PP, PVDF, etc.)
Metal (stainless
steel, steel, copper,
aluminum, etc.)
Note 2
10D for upstream and 5D for down-
stream (D: internal pipe diameter)
Refer to “Conditions on straight pipe”
for details.
Pipe material
Installation
method
V
V
Z
Fluid temperature
9th digit in code
symbol
Y...-20 to +100°C
A...0 to +120°C
-20 to 80C
range
Accuracy rating:
Response time: System cycle: 0.2s
Power consumption:
Permissible air volume rate:
Short-term thermal stability:
ø50 to ø600mm
ø50 to ø600mm
Internal diameter Velocity: 2m/s or higher Velocity: Less than 2m/s
Internal diameter Velocity: 2m/s or higher Velocity: Less than 2m/s
ø25 to ø50mm
Performance specifications
Plastic pipe
Metal pipe
Dead time: 0.2s or less, Time constant: 0.1s
15VA or less for AC power supply
5W or less for DC power supply
Up to 0.2% at 1 m/s (inversely proportional
to velocity)
140deg.C, 30min (in case FLSE 2)
Note: Use FLSE31/FLSE41 at the tempera-
±2.5% of rating
±1.5% of rating
±2% of rating
ture of 80°C or lower.
±0.05m/s
±0.03m/s
±0.04m/s

Related parts for EDS6-123I