EDS6-123I FUJI [Fuji Electric], EDS6-123I Datasheet - Page 3

no-image

EDS6-123I

Manufacturer Part Number
EDS6-123I
Description
ULTRASONIC FLOWMETER < M-Flow PW>
Manufacturer
FUJI [Fuji Electric]
Datasheet
Analog output: 4 to 20 mA DC (1 point)
Digital output: + total, - total, alarm, acting range, flow
Communication interface (option):
Display device: 2-color LED (Normal: green, Extraordinary:
Display language:
Velocity/Flow rate display:
Note: The “gal” means USgal.
Total display: Display of forward or reverse total
Velocity
Flow rate L/s, L/min, L/h, kL/h,
Total
Functional specifications
Transistor open collector: 1 point (DO1)
Mechanical relay contact: 1point (DO2), with socket
(exchangeable)
Metric system
m/s
ML/d, m
m
BBL/min, BBL/h,
MBBL/d
Metric system
mL, L, m
mBBL, BBL, kBBL
3
/h, Mm
Max. load resistance : 600 Ω
switch or total switch arbitrarily available
Capacity: 30V DC, 0.1A
Normal off/on selectable
Total pulse: 1pulse/day to 100pps (Pulse
width: 5, 10, 50, 100 or 200ms)
Normal close/open selectable
Capacity: 220V AC /30V DC, 1A
Mechanical expected life: More than 2 x 10
Total pulse: 1pulse/day to 1pps (Pulse width:
RS-232C equivalent / RS-485
Number of connectable units: one (RS-232C)/
Baud rate: 2400/4800/9600/19200 bps select-
Parity: None/Odd/Even selectable
Stop bit: 1 or 2 bits selectable
Cable length: up to 15m (RS -232C)/up to
Data: Velocity, flow rate, forward total, re-
red)
LCD with 2 lines of 16 characters and back
light
English, Japanese, French, German or Span-
ish selectable
Instantaneous velocity/flow rate display (The
flow of opposite direction is displayed by mi-
nus numerals.)
Numeral: 7 digits (decimal point be counted
Unit: Metric/Inch system selectable
Numeral: 7digits (decimal point be counted
Unit: Metric/Inch system selectable
operations (under rated load)
up to 31 (RS-485)
3
3
/s, m
verse total, status, etc.
, km
3
/d, BBL/s,
as 1digit)
as 1 digit)
3
able
3
50, 100 or 200ms)
/min,
, Mm
(resistive load)
1km (RS-485)
3
,
Inch system
ft/s
gal/s, gal/min, gal/h,
kgal/h, Mgal/d, ft
ft
BBL/s, BBL/min,
BBL/h, MBBL/d
Inch system
gal, kgal, ft
mBBL, BBL, kBBL,
ACRE-in, ACRE-ft
3
/min, ft
3
/h, Mft
3
, kft
3
, Mft
3
3
/d,
/s,
3
,
5
Configuration: Fully configurable from the 4-key pad (ESC,
Zero adjustment:
Damping:
Low flow cut off :
Alarm:
Burnout:
Bi-directional range:
Auto-2 ranges: Forward 2 ranges configurable independently
Flow switch: Lower and upper switching points configu-
Total switch: +total switching point configurable
Enclosure protection:
Mounting:
Acoustic coupler:
Material:
Sensor cable: 3D2V with outside diameter 5mm
Dimensions: Flow transmitter: H140 x W137 x D68mm
Mass:
Physical specifications
Hysteresis: 0 to 10% of acting range configurable
Hysteresis: 0 to 10% of acting range configurable
ter’s housing case by menu-driven software
Set Zero/Clear available
0 to 100s (every 1s) configurable for analog
output and display
0 to 5m/s configurable
Hardware fault/Process fault applicable to
digital output
Analog output : Hold/Over-scale/Under-scale/
Zero selectable
Total: Hold/Count selectable
Working timer: 0 to 100s (every 1s) configurable
Forward and reverse ranges configurable in-
dependently
Acting range applicable to digital output
Acting range applicable to digital output
rable independently
Acting point applicable to digital output
Acting point applicable to digital output
Jetproof type (IP65) both for converter and
detector (FLSE 2: When waterproof BNC
connector is provided)
FLSE 1: Immersion-proof type (IP67) (When
the terminal block is filled with silicon rubber
after wiring)
Flow transmitter: Wall or 2B pipe mount
Detector: Clamped on pipe surface
Silicon rubber or silicon-free grease
Flow transmitter: Plastic ABS
Detector (type: FLSE 2):
Detector (type: FLSE 1):
Detector: H50 x W228 x D34mm (FLSE1)
Flow transmitter: 0.8kg
Detector: 0.3kg (FLSE1) / 0.4kg (FLSE2)
1kg (FLSE3: mounting V method)
0.4kg (FLSE4: mounting Z method)
, , ENT) on the surface of flow transmit-
Plastic PBT for sensor housing,
SUS304 for guide frame
Plastic PBT for sensor housing,
SUS304 for sensor cover, SUS304
and PBT for guide rail
H50 x W348 xD34mm (FLSE2)
H40 x W500 x D80mm
H40 x W72 x D60mm
(FLSE3: mounting V method)
(FLSE4: mounting Z method)
3

Related parts for EDS6-123I