EP2S15 ALTERA [Altera Corporation], EP2S15 Datasheet - Page 139

no-image

EP2S15

Manufacturer Part Number
EP2S15
Description
Stratix II Device Family
Manufacturer
ALTERA [Altera Corporation]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2S15F484
Manufacturer:
ALTERA
0
Part Number:
EP2S15F484C3
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S15F484C3
Manufacturer:
ALTERA
0
Part Number:
EP2S15F484C3
Manufacturer:
ALTERA
Quantity:
60
Part Number:
EP2S15F484C3
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2S15F484C3N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2S15F484C3N
Manufacturer:
ALTERA
0
Part Number:
EP2S15F484C3N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2S15F484C3N
0
Part Number:
EP2S15F484C4
Manufacturer:
ALTERA30
Quantity:
146
Part Number:
EP2S15F484C4
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2S15F484C4N
Manufacturer:
ALTERA
Quantity:
325
Part Number:
EP2S15F484C4N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP2S15F484C5
Manufacturer:
ALTERA
Quantity:
528
Altera Corporation
May 2007
Notes to
(1)
(2)
(3)
(4)
(5)
(6)
T
I
I
I
I
Symbol
Symbol
I
OZ
C C I N T 0
CCPD0
Table 5–3. Stratix II Device Recommended Operating Conditions (Part 2 of 2)
Table 5–4. Stratix II Device DC Operating Conditions (Part 1 of 2)
J
Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply.
During transitions, the inputs may overshoot to the voltage shown in
The DC case is equivalent to 100% duty cycle. During transitions, the inputs may undershoot to –2.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
Maximum V
V
time, your Stratix II device does not configure successfully. If your system does not allow for a V
of 100 ms or less, you must hold nCONFIG low until all power supplies are reliable.
All pins, including dedicated inputs, clock, I/O, and JTAG pins, may be driven before V
are powered.
V
CCPD
C C I O
Table
Operating junction temperature
Input pin leakage current V
Tri-stated I/O pin
leakage current
V
(standby)
V
(standby)
must ramp-up from 0 V to 3.3 V within 100 μs to 100 ms. If V
maximum and minimum conditions for PCI and PCI-X are shown in parentheses.
CCINT
CCPD
5–3:
CC
supply current
Parameter
supply current
rise time is 100 ms, and V
Parameter
DC Electrical Characteristics
Table 5–4
V
V
load, no toggling
inputs
T
V
load, no toggling
inputs
T
V
O
J
J
I
I
I
CCPD
= V
= ground, no
= ground, no
= 25° C
= 25° C,
= V
shows the Stratix II device family DC electrical characteristics.
CC
CCIOmax
= 3.3V
CCIOmax
For commercial use
For industrial use
must rise monotonically from ground to V
Conditions
to 0 V
to 0 V
Conditions
(2)
EP2S15
EP2S30
EP2S60
EP2S90
EP2S130
EP2S180
EP2S15
EP2S30
EP2S60
EP2S90
EP2S130
EP2S180
(2)
C C P D
Table 5–2
Minimum Typical Maximum Unit
Stratix II Device Handbook, Volume 1
is not ramped up within this specified
Note (1)
–10
–10
DC & Switching Characteristics
based upon the input duty cycle.
Minimum
–40
0
0.25
0.30
0.50
0.62
0.82
1.12
C C
2.2
2.7
3.6
4.3
5.4
6.8
Note (1)
CCINT
.
, V
CCPD
Maximum Unit
CCPD
100
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
(3)
10
10
85
ramp-up time
, and V
CCIO
mA
mA
mA
mA
mA
mA
μA
μA
A
A
A
A
A
A
°C
°C
5–3

Related parts for EP2S15