MAX1254AEUE+ Maxim Integrated, MAX1254AEUE+ Datasheet - Page 15

no-image

MAX1254AEUE+

Manufacturer Part Number
MAX1254AEUE+
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1254AEUE+

Number Of Channels
10
Architecture
SAR
Conversion Rate
94 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Interface Type
Serial
Operating Supply Voltage
4.5 V to 5.5 V
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External
Table 2. Command Description
Table 3. Channel Address
with Internal Temperature Sensor and V
#### = Channel address code, see Table 3.
xxxx = These bits are ignored for this command.
ADDRESS IN COMMAND
COMMAND
Stand-Alone, 10-Channel, 12-Bit System Monitors
0000####
0010####
0011####
0100####
1000####
1010####
1100####
0001xxxx
0101xxxx
0110xxxx
0111xxxx
1001xxxx
1011xxxx
1101xxxx
1110xxxx
1111xxxx
WORD
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
______________________________________________________________________________________
BYTES TO
DATA BYTES AFTER
COMMAND WORD
DIN
N/A
N/A
N/A
20
0
0
0
0
0
0
0
0
0
2
5
5
FROM DOUT
Internal temperature
BYTES
N/A
N/A
N/A
20
0
3
2
5
5
0
0
0
0
0
0
0
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
INPUT
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
VDD
Manually Trigged Conversion
Read Alarm Register
Read Current Data Register for Selected Channel
Read Current Data Register for All Channels
Read Configuration Register for Selected Channel
Read Global Configuration Registers
Reserved
Reset
Clear Alarm/Fault for Selected Channels
Clear Alarm/Fault for All Channels
Write Current Data Register for Selected Channel
Write Current Data Registers for All Channels
Write Configuration Registers for Selected Channel
Write Global Configuration Registers
Reserved
Reserved
Before beginning a manual conversion, ensure the
scan mode bit in the setup register is zero, because a
logic 1 disables manual conversions. The address bits
in a Manually Triggered Conversion command select
the input channel for conversion (see Table 3). When
performing a differential conversion, use the even chan-
nel address (AIN0, AIN2, AIN4, AIN6); the command is
ignored if odd channel addresses (AIN1, AIN3, AIN5,
AIN7) are used for a differential conversion.
After issuing a Manually Triggered Conversion com-
mand, bring CS high to begin the conversion. To obtain
a correct conversion result, CS must remain high for a
period longer than the reference power-up time (if in
power-down mode) plus the conversion time for the
selected channel configured conversion type (voltage
or temperature). The conversion’s result can then be
read at DOUT by issuing a Read Current Data Register
for Selected Channel command, addressing the con-
verted channel. See Table 3 for channel addresses.
COMMAND DESCRIPTION
Manually Triggered Conversion
(Command Code = 0000)
DD
Monitor
15

Related parts for MAX1254AEUE+