MAX1254AEUE+ Maxim Integrated, MAX1254AEUE+ Datasheet - Page 24

no-image

MAX1254AEUE+

Manufacturer Part Number
MAX1254AEUE+
Description
Analog to Digital Converters - ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1254AEUE+

Number Of Channels
10
Architecture
SAR
Conversion Rate
94 KSPs
Resolution
12 bit
Input Type
Single-Ended/Differential
Interface Type
Serial
Operating Supply Voltage
4.5 V to 5.5 V
Number Of Converters
1
Voltage Reference
Internal 4.096 V or External
Stand-Alone, 10-Channel, 12-Bit System Monitors
with Internal Temperature Sensor and V
The temperature measurement process is fully auto-
mated in the MAX1253/MAX1254. All steps are
sequenced and executed by the MAX1253/MAX1254
each time an input channel (or an input channel pair)
configured for temperature measurement is scanned.
The resulting 12-bit, two’s complement number repre-
sents the sensor temperature in degrees Celsius, with
1 LSB = +0.125°C.
The MAX1253/MAX1254 support both single-ended
and differential temperature measurements.
The MAX1253/MAX1254 are autonomous subsystems,
requiring only initialization to scan, convert, and monitor
the voltage signals or the temperature sensors con-
nected to their input channels.
For simple applications, using any number of the input
channels and any combination of voltage/temperature
and unipolar/differential, with no interrupt generation
required, use the following intitialization procedure:
• Issue a Write Global Configuration Registers com-
Immediately after the global configuration register is
loaded, the MAX1253/MAX1254 begin to update the
current data registers. Acquire conversion data from
Table 15. Power-Up/Reset Defaults Summary
24
mand. This is a single, 5-byte write operation that con-
figures the input channels, enables the channels to be
used, sets the sample wait time between scans, con-
figures the interrupt output INT, selects the reference
mode, and starts the automatic scan mode. See the
Write Global Configuration Registers Command sec-
tion, Table 2, and Tables 5–10.
______________________________________________________________________________________
Channel configuration
Current data registers
Input configuration
Upper threshold
Lower threshold
Channel enable
Alarm register
REGISTER
Setup
MAX1253/MAX1254 Subsystem
Applications Information
BIT RANGE
B0 to B11
B0 to B11
B0 to B23
B0 to B7
B0 to B7
B0 to B9
B0 to B9
B0 to B9
Setting Up the
POWER-UP/RESET STATE
200hex
All 0s
All 1s
All 0s
All 0s
All 0s
All 1s
All 0s
the MAX1253/MAX1254 by issuing a command to read
a specific channel with the Read Current Data Register
for Selected Channel command. Read all current data
registers at once with the Read Current Data Registers
for All Channels command.
For more complex applications, the monitoring and
interrupt generation features of the MAX1253/MAX1254
require a second step of initialization. Each enabled
channel to be monitored requires configuration using a
Write Configuration Register for Selected Channel com-
mand. Each command is a 5-byte write that sets the
upper and lower fault thresholds, the number of faults for
an alarm before an interrupt is generated, and an aver-
age algorithm parameter if the application requires input
signal filtering.
Applications can read the current data registers and
respond to interrupts signaled by the INT output (see
the Servicing Interrupts at INT section).
All the MAX1253/MAX1254 registers can be verified by
reading back written data, including the configuration
registers. This feature is useful for development and
testing (see Table 2).
At initial power-up or after a RESET command, the
setup register resets to 00 hex. Consequently, the
MAX1253/MAX1254 are configured as follows:
• Sample wait time is 0µs.
• INT output is open drain and outputs an active-low
• Manual conversion mode.
• External reference for voltage measurements.
signal to signify an alarm.
Power-Up/Reset Defaults Summary
Setup Register Power-Up/Reset Defaults
See Setup Register Power-Up/Reset Defaults
All channels (int/ext) enabled
All single-ended voltage inputs
No alarms set
Faults = 0, no averaging
All upper thresholds max range
All lower thresholds min range
Set at midrange
COMMENTS
DD
Monitor