MAX11014BGTM+ Maxim Integrated, MAX11014BGTM+ Datasheet - Page 60

no-image

MAX11014BGTM+

Manufacturer Part Number
MAX11014BGTM+
Description
Special Purpose Amplifiers Auto RF MESFET Amp Drain-Current Cntrlr
Manufacturer
Maxim Integrated
Series
MAX11014, MAX11015r
Datasheet

Specifications of MAX11014BGTM+

Rohs
yes
Common Mode Rejection Ratio (min)
90 dB
Operating Supply Voltage
0.5 V to 11 V
Supply Current
2.8 mA
Maximum Power Dissipation
2162.2 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFN-48
Available Set Gain
13.98 dB
When performing a write operation, the first 3 LUTDAT
bits, D15, D14, and D13 are don’t care. When perform-
ing a read operation, these bits are set to the LUT data
channel tag 110. Bits D12–D7 set the size of the LUT in
binary format. Set the LUT size between 8 (001000)
and 48 (110000). Bits D6, D5, and D4 set the hysteresis
Automatic RF MESFET Amplifier
Drain-Current Controllers
Table 28. LUT Addresses
Table 28a. LUT Data Register Memory Map
X = Don’t care.
60
0000 0000 to 0010 1111
0011 0000 to 0101 1111
0110 0000 to 1000 1111
1001 0000 to 1011 1111
Configuration
Configuration
Configuration
Configuration
KLUT1 Base
KLUT2 Base
TLUT1 Base
TLUT2 Base
LUTADD7–LUTADD0
ADDRESS
KLUT1
KLUT2
KLUT1
KLUT2
NAME
TLUT1
TLUT2
TLUT1
TLUT2
______________________________________________________________________________________
1100 0000
1100 0001
1100 0010
1100 0011
1100 0100
1100 0101
1100 0110
1100 0111
LUTADD7–
LUTADD0
90 to BF
00 to 2F
30 to 5F
60 to 8F
(HEX)
C0
C1
C2
C3
C4
C5
C6
C7
00 to 2F
30 to 5F
60 to 8F
90 to BF
HEX
LUTDAT15
C0
C1
C2
C3
C4
C5
C6
C7
D15
1
1
1
1
1
1
1
1
1
1
1
1
D14
TLUT1-0 to TLUT1-47
TLUT2-0 to TLUT2-47
KLUT1-0 to KLUT1-47
KLUT2-0 to KLUT2-47
TLUT1 configuration
TLUT2 configuration
KLUT1 configuration
KLUT2 configuration
TLUT1 base
TLUT2 base
KLUT1 base
KLUT2 base
1
1
1
1
1
1
1
1
1
1
1
1
FUNCTION
D13
0
0
0
0
0
0
0
0
0
0
0
0
D12
X
X
X
X
X
X
X
X
MSB
MSB
MSB
MSB
MSB
MSB
MSB
MSB
D11
bit threshold. Using the temperature LUT as an exam-
ple, if the HYS value is 101 (16 bits) and the latest tem-
perature measurement differs from the last one by more
than 2°C, a new TLUT operation is performed and a
new TLUT value is calculated. Bits D3–D0 set the LUT
step size. See Table 28c. The step size is based on the
value of 2
STEP bits. Set the step size between 1 (2
(2
Do not write to these locations.
The following two-step sequence determines the
respective channel’s temperature or KLUT base value:
1) Set the LUTADD bits in the LUT address register to
2) Write to the LUT data register (LUTDAT15–
D10
9
). Locations 1010 (2
C4h (TLUT1), C5h (TLUT2), C6h (KLUT1) and C7h
(KLUT2). See Table 28d.
LUTDAT0) to initialize the base word. The KLUT
base value is stored in binary format, with the LSB
equaling 1. The TLUT base value is stored in two’s-
complement format, with the LSB equaling
+0.125°C.
D9
See Table 28b for bit details.
See Table 28b for bit details.
See Table 28b for bit details.
See Table 28b for bit details.
N
D8
, with N equaling the digital value of the
D7
D6
10
) to 1111 (2
D5
D4
D3
15
) are reserved.
D2
0
) and 512
LUT Base
LUTDAT0
D1
LSB
LSB
LSB
LSB
LSB
LSB
LSB
LSB
D0

Related parts for MAX11014BGTM+