MAX11014BGTM+ Maxim Integrated, MAX11014BGTM+ Datasheet - Page 65

no-image

MAX11014BGTM+

Manufacturer Part Number
MAX11014BGTM+
Description
Special Purpose Amplifiers Auto RF MESFET Amp Drain-Current Cntrlr
Manufacturer
Maxim Integrated
Series
MAX11014, MAX11015r
Datasheet

Specifications of MAX11014BGTM+

Rohs
yes
Common Mode Rejection Ratio (min)
90 dB
Operating Supply Voltage
0.5 V to 11 V
Supply Current
2.8 mA
Maximum Power Dissipation
2162.2 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Package / Case
TQFN-48
Available Set Gain
13.98 dB
If the hardware configuration register’s CKSEL1 or
CKSEL0 bits are changed while the ADC is performing
a conversion (or series of conversions), the
MAX11014/MAX11015 reacts in one of three ways:
Figure 32. Clock Mode 11 Timing Example 2
INTERNALLY*
*ALL TIMING SPECIFICATIONS ARE TYPICAL.
CLOCK MODE TIMING EXAMPLE 2: COMMANDS A SCAN OF CHANNELS 5, 6, AND 10 WITH AN INTERNAL REFERENCE.
CKSEL1/CKSEL0 = 00 and is then changed to
another value:
The ADC completes the already triggered series of
conversions and then goes idle. The BUSY output
remains high until the conversions are completed.
The MAX11014/MAX11015 then responds according
to commands with the new clock mode.
CKSEL1/CKSEL0 = 01 and is then changed to
another value:
If waiting for the initial external trigger, the
MAX11014/MAX11015 immediately exit clock
mode 01, power down the ADC, and go idle.
If a conversion sequence is in progress, that conver-
sion is completed and then the ADC goes idle. The
BUSY output remains high until the conversions are
completed. The MAX11014/MAX11015 then respond
according to commands with the new clock mode.
CKSEL1/CKSEL0 = 11 and is then changed to
another value:
CNVST
CONVERSION REGISTER TO
BUSY
WRITE TO THE ADC
SET UP THE SCAN
Changing Clock Modes During ADC
______________________________________________________________________________________
INT REFERENCE POWERS UP IN 45μs
t
PUINT
Automatic RF MESFET Amplifier
Conversions
INTO THE FIFO
CH5 LOADED
IDLE, BUT REFERENCE
STAYS POWERED UP
Drain-Current Controllers
t
When switching between continuous and single convert
modes, the clock mode requires resetting to avoid
hanging the ADC sequencing routine. To turn off con-
tinuous convert, complete the following sequence:
1) Turn off the selected channels but leave the continu-
2) Turn off the continuous convert bit.
3) Change from the current clock mode to any other
4) Change the clock mode back.
5) Clear the FIFO.
6) Perform the single conversion.
7) Read the FIFO results.
8) Turn continuous convert back on.
Turning on continuous convert can be done by setting
the CONCONV bit in the ADCCON register.
CNV11
ous convert bit asserted.
mode.
If waiting for an external trigger, the MAX11014/
MAX11015 immediately exit clock mode 11, power
down the ADC, and go idle. The BUSY output
stays low and waits for the external trigger.
If a conversion sequence is in progress, that con-
version is completed and then the ADC goes idle.
TEMPERATURE CONVERSION IN
Turning the Continuous Convert Bit On and Off
30μs
TEMPERATURE) RESULT
LOADED INTO THE FIFO
CH6 (EXTERNAL
IDLE, BUT REFERENCE
AND TEMPERATURE
SENSOR STAY
POWERED UP
t
ACQ11
CH10 LOADED
INTO THE FIFO
TEMPERATURE SENSOR
AUTOMATICALLY
REFERENCE AND
END OF SCAN,
POWER DOWN
65