NTS0102DP,125 NXP Semiconductors, NTS0102DP,125 Datasheet - Page 5

no-image

NTS0102DP,125

Manufacturer Part Number
NTS0102DP,125
Description
Translation - Voltage Levels XLATE REC 6.5V 250mW
Manufacturer
NXP Semiconductors
Datasheet

Specifications of NTS0102DP,125

Rohs
yes
Supply Voltage - Max
+ 6.5 V
Supply Voltage - Min
- 0.5 V
Maximum Operating Temperature
+ 125 C
Package / Case
TSSOP-8
Maximum Power Dissipation
250 mW
Minimum Operating Temperature
- 40 C
Factory Pack Quantity
3000

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NTS0102DP,125
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
Table 3.
8. Functional description
Table 4.
[1]
[2]
9. Limiting values
Table 5.
In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V).
NTS0102
Product data sheet
Symbol
B2, B1
GND
V
A2, A1
OE
V
n.c.
Supply voltage
V
1.65 V to V
1.65 V to V
GND
Symbol
V
V
V
V
I
I
I
I
IK
OK
O
CC
CC(A)
CC(B)
CC(A)
CC(A)
CC(B)
I
O
H = HIGH voltage level; L = LOW voltage level; X = don’t care; Z = high-impedance OFF-state.
When either V
[2]
CC(B)
CC(B)
Pin description
Function table
Limiting values
Pin
SOT505-2, SOT833-1,
SOT1089 and SOT996-2
1, 8
2
3
4, 5
6
7
-
Parameter
supply voltage A
supply voltage B
input voltage
output voltage
input clamping current
output clamping current
output current
supply current
CC(A)
7.2 Pin description
or V
V
2.3 V to 5.5 V
2.3 V to 5.5 V
GND
CC(B)
CC(B)
[1]
[2]
is at GND level, the device goes into power-down mode.
Dual supply translating transceiver; open drain; auto direction sensing
SOT1160-1
5, 8
9
2
1, 10
4
6
3, 7
All information provided in this document is subject to legal disclaimers.
Conditions
A port and OE input
B port
Active mode
Power-down or 3-state mode
V
V
V
I
CC(A)
I
O
O
A or B port
A port
B port
< 0 V
< 0 V
= 0 V to V
Rev. 4 — 23 January 2013
Input
OE
L
H
X
or I
CC(B)
SOT1309
6, 7
4
1
3, 2
5
8
-
CCO
Description
data input or output (referenced to V
ground (0 V)
supply voltage A
data input or output (referenced to V
output enable input (active HIGH; referenced to
V
supply voltage B
not connected
CC(A)
Input/output
An
Z
input or output
Z
)
[1][2]
[1][2]
[1][2]
[1]
[2]
Min
0.5
0.5
0.5
0.5
0.5
0.5
0.5
50
50
-
-
Bn
Z
output or input
Z
-
Max
+6.5
+6.5
+6.5
+6.5
V
+4.6
+6.5
-
50
100
CCO
NTS0102
© NXP B.V. 2013. All rights reserved.
+ 0.5
CC(B)
CC(A)
)
)
Unit
V
V
V
V
V
V
V
mA
mA
mA
mA
5 of 27

Related parts for NTS0102DP,125