L6472H STMicroelectronics, L6472H Datasheet - Page 26

no-image

L6472H

Manufacturer Part Number
L6472H
Description
Motor / Motion / Ignition Controllers & Drivers Motor DRV SPI dSPIN 7.0A 3.0 rms 8 - 45V
Manufacturer
STMicroelectronics
Type
2 Phase Stepper Motor Driverr
Datasheet

Specifications of L6472H

Product Category
Motor / Motion / Ignition Controllers & Drivers
Rohs
yes
Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
8 V to 45 V
Supply Current
0.5 mA
Operating Temperature
- 25 C to + 125 C
Mounting Style
SMD/SMT
Package / Case
HTSSOP-28
Power Dissipation
5 W

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6472HTR
Manufacturer:
ST
0
Part Number:
L6472HTR
0
Functional description
6.7.6
26/68
GoUntil and ReleaseSW commands
In most applications the power-up position of the stepper motor is undefined, so an
initialization algorithm driving the motor to a known position is necessary.
The GoUntil and ReleaseSW commands can be used in combination with external switch
input (see
The GoUntil command makes the motor run at the target constant speed until the SW input
is forced low (falling edge). When this event occurs, one of the following actions can be
performed:
If the SW_MODE bit of the CONFIG register is set to e0f, the motor does not decelerate but
it immediately stops (as a HardStop command).
The ReleaseSW command makes the motor run at the programmed minimum speed until
the SW input is forced high (rising edge). When this event occurs, one of the following
actions can be performed:
If the programmed minimum speed is less than 5 step/s, the motor is driven at 5 step/s.
ABS_POS register is set to zero (home position) and the motor decelerates to zero
speed (as a SoftStop command)
ABS_POS register value is stored in the MARK register and the motor decelerates to
zero speed (as a SoftStop command).
ABS_POS register is set to zero (home position) and the motor immediately stops (as a
HardStop command)
ABS_POS register value is stored in the MARK register and the motor immediately
stops (as a HardStop command).
Section
6.13) to easily initialize the motor position.
Doc ID 022729 Rev 2
L6472

Related parts for L6472H