Description
IC SDRAM 256MBIT 133MHZ 54BGA
Manufacturer
ISSI, Integrated Silicon Solution Inc
Datasheet

Specifications of IS42S16160D-75EBLI

Format - Memory
RAM
Memory Type
SDRAM
Memory Size
256M (16Mx16)
Speed
133MHz
Interface
Parallel
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 85°C
Package / Case
54-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S16160D-75EBLI
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Part Number:
IS42S16160D-75EBLI
Manufacturer:
ISSI
Quantity:
1 000
Part Number:
IS42S16160D-75EBLI
Manufacturer:
ISSI
Quantity:
20 000
Part Number:
IS42S16160D-75EBLI-TR
Manufacturer:
ISSI, Integrated Silicon Solution Inc
Quantity:
10 000
Company:
Part Number:
IS42S16160D-75EBLI-TR
Quantity:
8 113
BA1 are treated as “Don’t Care.” Once a bank has been
state longer than the refresh period (64ms) since no refresh
operations are performed in this mode.
The power-down state is exited by registering a NOP or
IS42S83200D, IS42S16160D
IS45S83200D, IS45S16160D
PRECHARGE
The PRECHARGE command (see figure) is used to deac-
tivate the open row in a particular bank or the open row in
all banks.The bank(s) will be available for a subsequent row
access some specified time (t
command is issued. Input A10 determines whether one or
all banks are to be precharged, and in the case where only
one bank is to be precharged, inputs BA0, BA1 select the
bank. When all banks are to be precharged, inputs BA0,
precharged, it is in the idle state and must be activated
prior to any READ or WRITE commands being issued to
that bank.
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses
are in progress. If power-down occurs when all banks are
idle, this mode is referred to as precharge power-down;
if power-down occurs when there is a row active in either
bank, this mode is referred to as active power-down.
Entering power-down deactivates the input and output
buffers, excluding CKE, for maximum power savings while
in standby. The device may not remain in the power-down
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
POWER-DOWN
48
cks
COMMAND
). See figure below.
CKE
CLK
All banks idle
Enter power-down mode
rp
) after the PRECHARGE
t
NOP
CKS
Input buffers gated off
less than 64ms
PRECHARGE Command
Exit power-down mode
A0-A9, A11, A12
Integrated Silicon Solution, Inc. — www.issi.com
BA0, BA1
CKE
RAS
CAS
CLK
A10
WE
CS
≥ t
CKS
NOP
HIGH
DON'T CARE
ACTIVE
BANK ADDRESS
BANK SELECT
ALL BANKS
t
t
t
RCD
RAS
RC
04/05/2010
Rev. D